User's Manual

32
5.4. CTC-1041RV Programming Command Table
DTMF
CHARACTER
COMMANDS
DTMF
ACK
COMMAND OPERATION
TERMI-
NATOR
DTMF
ACK
DEFAULT
01# Bi Telephone number 1 # Bi
No number
02# Bi Telephone number 2 # Bi
No number
03# Bi Telephone number 3 # Bi
No number
04# Bi Telephone number 4 # Bi
No number
05# Bi
Telephone number for alarm report # Bi
1,2,3,4
06# Bi
Telephone number for status report # Bi
1,2,3,4
07# Bi Telephone number for Non-Emergency Call # Bi Disable
10# Bi
Global account number, 4 to 6 digits # Bi
No account
number
11# Bi
4-6 digits Account number 1 (Tel. Number 1) # Bi
No account
number
12# Bi
4-6 digits Account number 2 (Tel. Number 2) # Bi
No account
number
13# Bi
4-6 digits Account number 3 (Tel. Number 3) # Bi
No account
number
14# Bi
4-6 digits Account number 4 (Tel. Number 4) # Bi
No account
number
20# Bi
All formats the same, 0 = Contact ID,
1= Scancom, 2 = Tunstall, 3 = Voice
# Bi
Contact ID
21# Bi
0 = Contact ID, 1= Scancom, 2 = Tunstall,
3 = Speech (Tel. Number 1)
# Bi
Contact ID
22# Bi
0 = Contact ID, 1= Scancom, 2 = Tunstall,
3 = Speech (Tel. Number 2)
# Bi
Contact ID
23# Bi
0 = Contact ID, 1= Scancom, 2 = Tunstall,
3 = Speech (Tel. Number 3)
# Bi
Contact ID
24# Bi
0 = Contact ID, 1= Scancom, 2 = Tunstall,
3 = Speech (Tel. Number 4)
# Bi
Contact ID
31# Bi
Ringer enable, 0 = Disable, 1 = Enable # Bi
Ringer Disabled
32# Bi
Audible fault alert, 0 = Off, 1 = On # Bi
Off
33# Bi
Help arrived signalling,
0 = Off, 1 = On
# Bi
Help arrived
signalling On
34# Bi
Emergency button enable
0 = Button off, 1 = Button on
# Bi
Emergency
button On
35# Bi
Silent Mode
0 = Silent mode On, 1 = Silent mode Off
# Bi
Silent mode Off
37# Bi
AC fault report, 0 = Off, 1 = On # Bi
On
38# Bi
Follow-On & Call Back Function, 0 = Follow-
On, 1= Call-Back, 2= Follow-On & Call-Back
# Bi
Follow-On
39# Bi
Dialling Mode
0 = Tone, 1 = Pulse
# Bi Tone
40# Bi
Set Access Code # Bi
1111
41# Bi
Auto answer for Remote programming,
00 = None, 01 - 32 = Auto answer 1 - 32 rings
# Bi
20 rings