Getting Started Guide

Sensitivity Dip Switch 1 Dip Switch 2 Detection Range
Maximum OFF OFF 8m
Medium OFF ON 5m
Low ON OFF 3m
Minimum ON ON 1.5m
Test Mode
The Test mode is used to help check the Glass Break Detectors detection distance. When the
Learn/Test button is pressed, the Glass Break Detector will enter Test mode for 5 minutes. Pressing the
button again during the 5-minute period will reset test mode time to 5 minutes.
During Test mode, both Red and Green LEDs will light up when glass break is detected.
Testing the Detector
The Detector should be tested to ensure it is able to detect glass breakage successfully. A FlexGuard
FG-701 Glassbreak Simulator is required to test the detection function.
1 Press Learn/Test button once to put Detector into Test mode for 5 minutes.
2 Set the FlexGuard FG-701 to FLEXand TESTmode.
3 Put FG-701 at desired testing location on the glass and point the speaker at the Detector. Close the
window covering if it is present.
4 Strike the glass with a cushioned tool to create a glass striking sound. When FG-701 detects the glass
striking sound, it will react by emitting glass break sound.
5 The Detector will only be activated if it detects both glass striking and glass break sounds. When
activated, both Green and Red LED will light up to indicate glass break has been detected.
Supervision Function
When the Glass Break Detector is in normal operation, it will transmit a supervision signal regularly
every 30~50 minutes.
Battery
The Glass Break Detector uses a 3V CR123A Lithium battery.
The Glass Break Detector can detect low battery voltage. When low battery voltage is detected, a low
battery signal will be sent to the Control Panel along with regular signal transmissions for the Control
Panel to display the status accordingly.
When changing battery, press the learn/test button a couple times to discharge after removing battery
before inserting a new one.
Glass Thickness
Plated Glass: 2.4 to 6.4 mm (3/32 to 1/4")
Tempered Glass: 2.4 to 6.4 mm (3/32 to 1/4")
Wired Glass: 3.2 to 6.4 mm (1/8 to 1/4")
Laminated Glass 3.2 to 6.4 mm (1/8" to 1/4")
Installation
The Glass Break Detector should be mounted on ceiling or wall. There should be no obstacle between
the Detector and the window protected. The Detector back cover has mounting knockouts which can
be broken for screw mounting. Alternatively, you may also mount the detector with double side
adhesive tape provided.
Mounting Location:
Mount away from sound source, such as speaker, air condition or motor.
Mount with as much distance from window or door as possible to avoid external sound interference.
Screw Mounting
1 Break through the knockouts on back cover and use them as template to mark position on wall/ceiling.
2 Drill holes at marked location and screw the back cover onto the wall/ceiling, insert wall plug if needed.