User's Manual

2
Features
z
L
L
E
E
D
D
S
S
t
t
r
r
o
o
b
b
e
e
L
L
i
i
g
g
h
h
t
t
1. The strobe light includes 3 LEDs (From right to left: LED 3-> LED 2->LED 1).
Refer to below table for LED and siren beep for status indication.
<
<
N
N
O
O
T
T
E
E
>
>
) Arm/Home/Disarm LED and siren beep behaviour are the same under fault conditions
(Tamper Fault/Low Battery).
z
z
A
A
l
l
a
a
r
r
m
m
A
A
c
c
t
t
i
i
v
v
a
a
t
t
i
i
o
o
n
n
When an alarm is activated, the Bellbox will activate its siren and strobe light according to different
alarm type:
z Burglar and Emergency alarm: Continuous alarm, all LED flashes.
z Fire alarm: 2-second alarm with1-second interval, all LED flashes.
z
z
A
A
l
l
a
a
r
r
m
m
L
L
e
e
n
n
g
g
t
t
h
h
S
S
e
e
t
t
t
t
i
i
n
n
g
g
When the Bellbox receives an alarm signal via Z-Wave network, it will activate siren and strobe
light according to the alarm length set by the system control panel (default is 10 minutes).
z
z
B
B
a
a
t
t
t
t
e
e
r
r
y
y
a
a
n
n
d
d
L
L
o
o
w
w
B
B
a
a
t
t
t
t
e
e
r
r
y
y
D
D
e
e
t
t
e
e
c
c
t
t
i
i
o
o
n
n
The Bellbox uses two 1.5V alkaline D-cell batteries as its power source. With the battery, use the
battery switch to power on/off the Bellbox manually.
The Bellbox features Low Battery Detection function. When the battery voltage is low, the Bellbox
will transmit Low Battery signal to the coordinator in Z-Wave network.
The Bellbox will report its battery percentage to the Control Panel respectively at 100%, 75%,
50%, 25%, 10%. If the battery voltage is low (10%), a Low Battery signal will be sent to the
Control Panel to notify the user.
When changing battery, after removing the old battery, press the Tamper Switch twice to fully
discharge before inserting new battery.
z
z
T
T
a
a
m
m
p
p
e
e
r
r
P
P
r
r
o
o
t
t
e
e
c
c
t
t
i
i
o
o
n
n
The Bellbox is protected by a tamper switch which is compressed against the mounting surface
when mounted. Whenever the Bellbox is removed from mounted location, or its cover opened, the
tamper switch will be activated and the Bellbox will send a tamper open signal to remind the user of
the condition and activate an alarm immediately.
z
z
A
A
d
d
d
d
i
i
n
n
g
g
D
D
e
e
v
v
i
i
c
c
e
e
(
(
I
I
n
n
c
c
l
l
u
u
s
s
i
i
o
o
n
n
)
)
This product can be included and operated in any Z-Wave network with other Z-Wave certified
devices from other manufactures and/or other applications. All non-battery operated nodes within
the network will act as repeaters regardless of vendor to increase reliability of the network.
z Insert the two 1.5V D-Cell alkaline batteries into the battery compartment connecting the
correct polarity as shown on the battery compartment lid.
z The Bellbox will emit a 2-tone beep.
z Put the Z-Wave gateway or control panel into Inclusion or Learning mode (please refer
to the Z-Wave gateway or control panel manual).
z Within 1.5 seconds, press the Function Button 3 times.
z Refer to the operation manual of the Z-Wave gateway or control panel to complete the
learn-in process.
z If the sensor has already been included (learnt) into another Z-Wave Gateway/Control
Panel, or if the sensor is unable to be learnt into the current Z-Wave Gateway/Control
Panel, please exclude it first (see Exclusion) before attempting to include it into the
current Z-Wave Gateway/Control Panel.
S
S
i
i
r
r
e
e
n
n
A
A
u
u
d
d
i
i
o
o
S
S
t
t
r
r
o
o
b
b
e
e
l
l
i
i
g
g
h
h
t
t
i
i
n
n
d
d
i
i
c
c
a
a
t
t
i
i
o
o
n
n
Arm 1 beep All 3 LED flash once
Home 1 beeps All 3 LED flash once
Disarm 2 beep Sequentially flash for 1 cycle
Entry/Exit Count Down 1 beep per second None
Door Chime 2 tone beeps None