Installation and Operation Guide

33
Item Command Example & Usage Default
Adjust
Speaker
Volume
SPKVL SPKVL:PROG,1111,3
Adjusts speaker volume of CH-MG
Parameter: 1-5 speaker volume
1 = minimum
5 = maximum
4
Set Caller ID CALID CALID:PROG,1111,1,0227942014
Parameter 1: Select Caller ID: 1 = ID #1, 2 = ID #2
Parameter 2: Caller ID number: Enter a number up to 15 digit long
--
Remote
Firmware
Upgrade
FWUG FWUG:PROG,1111,59.124.230.221,53033,/img/123.bin,042d
Upgrade CH-MG firmware by downloading firmware file from server
remotely.
Parameter 1: Server IP Address (Max 44 characters)
Parameter 2: Server Port Number
Parameter 3: File path(max 31 characters)
Parameter 4: crc16 check sum
Remove RF
Device
DEVRM DEVRM:PROG,1111,1
Remove RF Device in CH-MG
Parameter 1: Zone number to be removed (1~5)
Add RF
Device
DEVAD DEVAD: PROG,1111,1234567890
Add RF Device into CH-MG using device RF code
Parameter 1: Device RF Code (Max 10 digits)
--