User's Manual

Mounting
The Clamp Meter has a mounting bracket for mounting purposes.
1. Use the mounting bracket as template to mark the two holes on the wall for installing screws.
2. Screw the mounting bracket onto the wall according to marked location. Install wall plugs if necessary.
3. Locate the hooks of the mounting bracket and line up the hooks with the mounting holes on the Clamp
Meter. Fit the hooks into the mounting holes as picture below. Installation is now complete.
ZigBee Network Setup
ZigBee Device Guideline
ZigBee is a wireless communication protocol that is reliable and has low power consumption and high
transmission efficiency. Based on the IEEE802.15.4 standard, ZigBee allows a large amount of devices to
be included in a network and coordinated for data exchange and signal transmission.
Due to the fundamental structure of ZigBee network, ZigBee device will actively seek and join network after
powering on. Since performing a task in connecting network may consume some power, it is required to
follow the instructions to avoid draining battery of a ZigBee device
- Ensure your ZigBee network router or coordinator is powered on before inserting battery into the ZigBee
device.
- Ensure the ZigBee network router or coordinator is powered on and within range while a ZigBee device is
in use.
- Do not remove a ZigBee device from the ZigBee network router or coordinator without removing the battery
from a ZigBee device.
Joining the ZigBee Network
As a ZigBee device, the Clamp Meter needs to join a ZigBee network to be able to read the meter. Please
follow the steps bellow to join the Clamp Meter into ZigBee network.
The Clamp Meter has 2 ZigBee Endpoints representing 2 current transformers. When joining ZigBee
network, it will be recognized as 2 separate ZigBee devices and will occupy 2 zones in your ZigBee
network coordinator.
1. Plug in the AC Input cable into the socket to power on the Clamp Meter.
2. Press and hold the function button for 10 seconds and release to search for existing ZigBee network.
Please make sure the permit-to-join feature on the router or coordinator of your ZigBee network is
enabled.
3. After joining the ZigBee network, the Clamp Meter will be registered in the network automatically. Please
check the ZigBee coordinator, security system control panel or CIE (Control and Indicating Equipment) to
confirm if joining and registration is successful.
4. Under normal operation, if the Clamp Meter loses connection to its current ZigBee network, the LED
indicator will flash every 20 minutes to indicate the situation. Please check your ZigBee network condition
and Clamp Meter signal range to correct the situation.
Removing Device from ZigBee Network (Factory Reset)
To remove the device from current ZigBee network, the Clamp Meter must be put to Factory Reset to
complete device removal. Factory Reset function will clear the Clamp Meter of its stored setting information
and prompt the device to search for new ZigBee network.
Before removing device, make sure the Clamp Meter is within current ZigBee network signal range
1. Delete the Clamp Meter from current control panel / CIE.
2. Press and hold the function button for 10 seconds, then release the button to reset device.
3. Upon reset, the Clamp Meter will clear current ZigBee network setting and transmit signal to ZigBee
coordinator to remove itself from current ZigBee network. It will then actively search for available ZigBee
network again and join the network automatically.