User's Manual

Energy Consumption Monitor
The Clamp Meter will transmit a signal from the clamp itself with its power consumption data every 10
minutes to the ZigBee network coordinator.
Reading from clamp on Current Transformer Cable CT-1 is reported to ZigBee Endpoint 0x01.
Reading from clamp on Current Transformer Cable CT-2 is reported to ZigBee Endpoint 0x02.
Whenever the Clamp’s energy output changes by +/- 2W, the Clamp Meter will automatically transmit
a signal with power consumption data to the ZigBee network coordinator for update.
The Clamp Meter transmits a signal with power data to coordinator whenever accumulated power
usage of the clamp increases by 0.1kW/hr.
The Clamp has an accuracy of +/- 5%.
To clear the clamp of its accumulated power consumption data, follow steps below:
1. Un-plug AC cable to power down Clamp Meter.
2. Press and hold the function button, while holding the button, power on the Clamp Meter by
re-plug in the AC cable.
3. Release the function button when red LED starts to quickly flash.
4. Un-plug and re-plug AC cable again, clearing is complete.
Maximum Operation Load
110V: 6600W and 60A
230V: 13800W and 60A.
Appendix (For developers only)
Scene Selector Cluster ID
Device ID: Consumption Awareness Device :0x000D
Endpoint: 0x01
Server Side Client Side
Mandatory
Basic (0x0000) Identify (0x0003)
Identify(0x0003)
Metering (0x0702)
Optional
None None
Device ID: Consumption Awareness Device :0x000D
Endpoint: 0x02
Server Side Client Side
Mandatory
Basic (0x0000) Identify (0x0003)
Identify(0x0003)
Metering (0x0702)
Optional
None None
Attribute of Basic Cluster Information
Identifier Name Type Range Access Default
Mandatory
/ Optional
0x0000 ZCLVersion
Unsigned 8-bit
integer
0x00 –0xff
Read
only
0x01
M
0x0001 ApplicationVersion
Unsigned 8-bit
integer
0x00 – 0xff
Read
only
0x00
O
0x0003 HWVersion
Unsigned 8-bit
integer
0x00 –0xff
Read
only
0
O
0x0004 ManufacturerName
Character
String
0 – 32 bytes
Read
only
Climax
Technology
O
0x0005 ModelIdentifier
Character
String
0 – 32 bytes
Read
only
(Model Number)
O
0x0006 DateCode
Character
String
0 – 16 bytes
Read
only
20160620
O
0x0007 PowerSource 8-bit 0x00 –0xff Read M