User's Manual

Enumeration only
0x0010 LocationDescription
Character
String
0 – 32 bytes
Read /
Write
O
0x0011 PhysicalEnvironment
8-bit
Enumeration
0x00 –0xff
Read /
Write
0x00
O
0x0012 DeviceEnabled Boolean 0x00 –0x01
Read /
Write
0x01
M
Attribute of Identify Cluster Information
Identifier Name Type Range Access Default
Mandatory
/ Optional
0x0000 IdentifyTime
Unsigned
16-bit integer
0x00 0xffff
Read /
Write
0x0000
M
Attribute of the Metering Cluster Information
Identifier Name Type Range Access Default
Mandatory
/ Optional
0x0000 IdentifyTime
Unsigned
16-bit integer
0x00 - 0xffff
Read /
Write
0x0000
M
Attribute of the Metering Cluster Information
Identifier Name Type Range Access Default
Mandatory
/ Optional
0x00
CurrentSummation
Delivered
Unsigned
48-bit integer
0x000000000000
to
0xFFFFFFFFFFFF
Read
Only
0x00 M
Attributes of the Metering cluster Information
Identifier Name Type Range Access Default
Mandatory
/ Optional
0x00 UnitofMeasure
8-bit
Enumeration
0x00 to
0xFF
Read
Only
0x00 M
0x01 Multiplier
Unsigned 24-bit
Interger
0x000000
to
0xFFFFFF
Read
Only
1 O
0x02 Divisor
Unsigned 24-bit
Integer
0x000000
to
0xFFFFFF
Read
Only
0xF9 M
0x03 SummationFormating 8-bit BitMap
0x00 to
0xFF
Read
Only
0xF9 M
0x04 DemandFormating 8-bit BitMap
0x00 to
0xFF
Read
Only
0x94 O
0x06 MeteringDeviceType 8-bitMap
0x00 to
0xFF
Read
Only
0x00 M
Attributes of the Metering cluster Information
Identifier Name Type Range Access Default
Mandatory
/ Optional
0x00 InstantaneousDemand
Signed 24-bit
Integer
-8,388,607 to
8,388,607
Read
Only
0x00
O