+--E1 19-Dec-2012
Table of Contents 1. Application Overview _______________________________________________________ 1 1.1. Identifying The Parts ____________________________________________________________ 1 1.2. The Power Supply ______________________________________________________________ 2 1.3. Insert GPRS/3G SIM Card ________________________________________________________ 3 1.4. How to install the Control Panel __________________________________________________ 3 1.5.
4.4 Global Test ____________________________________________________________________ 26 4.5 Factory Reset __________________________________________________________________ 27 5. Appendix __________________________________________________________________ 27 5.1. CID Event Code ________________________________________________________________ 27 5.2. Tunstall Event Code____________________________________________________________ 28 5.3.
. 1. Application Overview RED HELP BUTTON (with backlight) — Back-lit disigned for easy access at night 1.1. Identifying The Parts — Backlight illuminates when off-hook TOP VIEW — Backlight flashes during the waiting period until help arrives 5. Microphone 6. Speaker REAR VIEW 1. GREEN LED — ON: AC Power is ON. — FLASH every second: AC Power failure 7. — FLASH every 2 seconds: Panel or Device Low battery — This slot is for inserting a SIM card. 8.
11. DC Jack — DC 12V connection 1.2. The Power Supply 1A switching power 12. Battery Switch 13. Local Programming Telephone Unit Input — A special telephone cord to connect CTC-1052 and your phone unit for Local Programming (optional). z An AC power adapter is required to connect to a wall outlet. Be sure only to use an adapter with the appropriate AC voltage rating to prevent component damage. A DC 12V output and 1A switching power is generally used to power CTC-1052.
1.3. Insert GPRS/3G SIM Card 1.4. How to install the Control Panel CTC-1052 Panel features built-in GPRS/3G communication facility to report to the Monitoring Station. z Locating a suitable position for the Control Panel To Insert SIM card: ) It is recommended to disable the SIM card PIN code before inserting into the Control Panel. The GPRS/3G SIM card base is located on the rear side of the unit: z Insert the SIM card with the chip side facing up.
2. Learn-in the Devices There are two methods to learn in devices: local learning and command learning. Total 10 sensors are allowed to be learnt into the system. Wrist Transmitter ---- WTR Pendant Transmitter ---- WTR Water Sensor ---- WS Fall Sensor Local Learning: 2.1. Learning Pendant #1 You can use the local learning method to learn in 2 devices only. Refere to 2.1 Learning Pendant # 1 to learn in the first device and then 2.2 Learning Pendant #2 to learn in the second one. Step 1.
in Learning Mode. The RED LED begins to flash. 2.2. Learning Pendant #2 Step 1. From Idle mode, press and hold the RESET button for 6 seconds Step 4. Press & hold the RESET key again for 6 seconds (once pressed, a button beep sound will be heard. CTC-1052 will emit one short beep at 3 sec., then a long beep when it reaches 6 sec.) Step 2. Once pressed, a button beep sound will be heard. CTC-1052 will emit one short beep at 3 sec., then a double beep when it reaches 6 sec. Step 5.
3.1.2. CTC-835 Programmer 3. System Configuration CTC-835 is a powerful programming tool (sold separetely) that features a built-in keypad and LCD display to help you to program the medical alarm panels effeciently and conveniently. It also features Once-for-All Uploading, which allows you program on a computer via the supplied Pilot software and you can then upload all the settings to the medical alarm panel simultaneously with a single mouse click. 3.1.
Short beep: Command succeeded Command 01-04 Long beep: Command failed Telephone Number Programming z Used to program the 1st - 4th Tel. numbers 4. Function Selection = According to different Command you will have different entering in this part, e.g. Tel. Number, Account number, etc. respectively. z To program the 1st Tel. number: enter (01) followed by (#). After one short beep, enter (telephone number) followed by (#). CTC1052 will emit one beep signaling the 1st Tel.
number & GPRS/IP (1-6) is/are to be used for Status Reporting. 2nd, 3rd & 4th Tel. #s (234) 1st, 2nd, 3rd & 4th Tel. #s (1234) Function Selection Sequence 1st, 2nd, 3rd, 4th Tel. & 5th GPRS. #s (12345) 1st Tel. # (1) (123456) 2nd Tel. # 1st, 2nd, 3rd, 4th Tel. 5th & 6th GPRS. #s (2) 3rd Tel. # (3) z Available Key-in options: Tel. Number / IP Address th 4 Tel. # (4) 5th GPRS1 # (5) th z Factory default is set as (123456).
z Factory default is set as (0) disable. Nonemergency call will be reported to all of 4 Telephone Numbers. Digital Reporting Method z Please refer to section 4.1.2 for more information. z Non-emergency calls can be made both Speech Method when the Control Panel has a normal AC power supply and when the Control Panel’s AC power fails. When the Control Panel has the AC failure condition, nonemergency can be made by pressing and hold the Reset button for 3 seconds.
) If any of SMS Reporting Methods is selected: Function Selection CID sent over SMS is a backup path when alarm can’t go through in digital reporting method. Once alarm or emergency data is successfully transmitted, the CTC-1052 will automatically send out a SMS (CID) Message. (0) Result OFF (No Warning Beep) ON (1) (With Warning Beep) z Factory Default is set as (0), OFF. z The fault situation includes Low Battery Fault (for both CTC-1052 and Devices) and AC Failure.
Command 34 Command 37 Emergency Button Enable AC Fault Report z The RED HELP BUTTON can be enabled z The CTC-1052 can be programmed to or disabled to send an Emergency alarm report: send a Fault Report when an AC power failure is detected. Function Selection (0) (1) Function Selection Result (0) OFF Result OFF (Send No Report) (Deactive) ON (1) ON (Active) z z Factory Default is set as (1), ON. (Send Report) Factory Default is set as (1), ON.
automatically enter the Follow-On mode as specified by Command (45). Command 42 Guard Time Delay Once Follow-On Mode is terminated, CTC1052 will automatically start a 5-minute waiting period to auto answer any incoming phone calls from the Monitoring Center. This command is deisgned for any compitable sensor, except Fall Sensor (fall detection). ) z CTC-1052 can be programmed to delay alarm reporting from (00) (instant reporting) to (99) seconds.
) Whenever programming mode is accessed, CTC-1052 will reset the Periodic Test Call timer. ) Periodic Test Call will only function with telephone numbers assigned to Digital or SMS reporting method in Command 20-24. ) The reporting method for mobility alarm is the same as the emergency alarm. The report will be sent based on your reporting methods without guard time waiting. ) When (00) is selected, no code is sent to Monitoring Center.
the time of the Check-in Report starts calculating. Center, it will automatically enter Listen-In Half Duplex for 1-10 minutes (set by Command 46) allowing the Monitoring Center Personnel to listen in to what is happening on the other side.
(3) (4) 6 Days 7 Days ) (5) 8 Days (6) 9 Days Whenever a SIM Card PIN code is entered, the system will check if the entered PIN code is matched. If not, the SIM card will be locked. (7) 10 Days ) This function is not used to change SIM Card PIN Code. If you want to change your SIM Card PIN Code, please use your cell phone to change it. ) If the SIM Card is locked, please contact your local telecommunication service provider. z Factory default is set as (0) Disable.
) Echo volume varies depending on adjustment of speaker volume and microphone sensitivity. To minimize the impact of echo, if you raise speaker volume, please be sure to lower microphone sensitivity, and vice versa. Function Selection Result (00) INSTANT REPORTING (01) - (99) DELAY z Factory Default is (15), 15 SECONDS. Command 64 Microphone Sensitivity Adjustment z This function is used to adjust microphone sensitivity. The microphone sensibility only can be adjusted in the two-way mode.
z If you have learned one device into the Step 2: Press the Pendant Button within 20 secs. system by using local learning method (as mentioned in 2.1 section), you are not allowed to use Command 91 to learn in another device. z For learning Pendant #1: Step 1: Enter 91 + # on the phone set, then a short beep will be heard via the phone set. Step 2: Press the Pendant Button within 20 secs. ) ) ) Learning can only be completed within the signal reception range of CTC-1052.
removed from the system first. ) 9 9 successfully. If one long beep is emitted instead of 2 beeps, it indicates: The device has already been learnt-in. Another device has been learntin before. ) Adding a Pendant for a second time is prohibited unless it is removed from the system first.
3.3. SMS Remote Programming 4. Operation 4.1. Idle Mode ) When the system is in Idle Mode, CTC-1052 is ready to execute the following functions: Prior to procced, please be reminded to change the language setting of your mobile phone to English. 4.1.1. Answering Incoming Phone Calls Step 1: Use your handset and go into the SMS edit screen. This function is only available when Command #31 is set as ON (factory default is OFF). Step 2: Enter the SMS keyword (default is PROG).
way voice communication between the call recipient and CTC-1052 for 30 minutes. The Red button backlight will illuminate during the communication. 4.1.2. Non-Emergency Speech Call This function is only available when Command #7 is programmed. Normal AC Power Supply ) Step 1. From Idle mode, press and hold the RESET button for 3 seconds until CTC-1052 emits a short beep. Step 2. Release the button and one short beep will sound. CTC-1052 dials the phone number entered in Command #7. Step 3.
Monitoring Center and the GREEN LED flashes slowly. 4.1.7. Automatic Check-in Report = Periodic Test Call z If Low Battery condition persists, CTC1052 will emit 2 short beeps every hour. z z After the battery voltage is restored and lasts for 12 hours, CTC-1052 will send Battery Restore report to Monitoring Center and the GREEN LED returns to steady ON. When CTC-1052 is programmed to send a periodical check-in report, CTC-1052 will report to the Monitoring Center accordingly.
z Disable the Mobility function in idle mode: With the phone number 0987654321, the format should either INCLUDE or EXCLUDE Contry Code, which is “886” for Taiwan as below: Step 1: When the system is in Idle Mode, press & hold the Reset Button for 16 seconds. Step 2: During the 16-sec period, CTC-1052 will emit one short beep Æ a double beep Æ continuous three short beeps Æ a long beep.
z The first alarm reporting priority is GPRS Reporting Method. service provider. Please inquire your service provider for your GPRS username. If no username is required, you may skip this step. Confirmation Beeps z z Once Guard Time Delay expires, CTC-1052 will summon help based on the programmed reporting method.
COMMUNICATION Enter (3) to LISTEN-IN ONLY End a Call: enter (9) to HANG UP or put the handset back into the base cradle. Enter (7) to Speaker Volume Control and then press (6) or (4) to increase or decrease levels of speaker volume in the “Two-Way” communication mode. Enter (8) to Microphone Sensitivity Control and then press (6) or (4) to increase or decrease levels of microphone sensitivity in the “TwoWay” communication mode.
next use. Please note that when a particular DTMF key is pressed, its designed shortcut function will be executed & the communication time will be extended at the same time. ) Please note that if you wish to enable a designed shortcut function, please press DTMF keys over 1 second to enable the function you desire. ) If the levels of speaker volume and microphone sensitivity can only be adjusted in the two-way communication mode, the adjusted value will be kept at next use.
Speech Reporting Method backlight dims. z If Speech Reporting Method is selected, after dialing, CTC-1052 will open a twoway voice communication between the Call Recipient and CTC-1052 for 1-10 minutes (set by Command #46). z At 20 & 10 seconds before the time period expires, CTC-1052 will emit two beeps via the telephone handset to alert the user.
Step 2. Within 5 secs, press Pendant button. 5. Appendix Step 3. CTC-1052 will emit a short beep and report to Monitoring Center. 5.1. CID Event Code z 100 - Panel emergency When Red HELP button is pressed. z 101 - Personal emergency 4.5 Factory Reset When the Wrist Transmitter / Emergency Pendant (WTR) or Fall Sensor is pressed. CTC-1052 will clear all programmed parameters by the following sequence: z 102 –Inactivity Step 1. Unplug the power cord from the DC Jack.
flashes every 2 sec with 2 short beeps every hour. 5.2. Tunstall Event Code z D#1011 - Panel AC Restored z 333 - No WTR Learnt-in When CTC-1052 has learned-in previously. no When AC power is restored to CTC- WTR 1052. z D#1012 - Global test & Periodic test ) report This event code will be sent with a fixed zone number of 072 When CTC-1052 reports Global Test to monitoring Center. z 373 - Smoke Low Battery When CTC-1052 reports Periodic test call to monitoring Center.
with a beep every 30 secs. sec with 2 short beeps every hour. When CTC-1052 is under Battery Not z D#1019 – Panel Low Battery / Panel Connected status, the Green LED flashes every 2 sec with 2 short beeps every hour. Battery Disconnection When CTC-1052 is under Low Battery status, Green LED flashes every 2 secs with 2 short beeps every hour.
triggered or Smoke Detector’s test button is pressed. When Carbon Monoxide Detector (CO) is triggered or Carbon Monoxide Detector’s test button is pressed. z 355555557 - SD or CO emergency restore When the Smoke Detector (SD) or Carbon Monoxide Detector emergency status is restored. (CO) FCC Statement This device complies with Part 15 of the FCC Rules.
5.4.
DTMF DTMF CHARACTER COMMANDS ACK 44# Bi 45# Bi 46# Bi 47# Bi 49# Bi 61# Bi 62# Bi COMMAND OPERATION Mobility time 00= Disable, 01 ~ 36= 1 ~ 36 Hours Follow-On Choice, 0 = Wait command, 1 = Listen, 2 = Two way voice communication Follow-On mode & Two-Way Period, 01=1 min, 02=2mins, 03=3mins, 04=4mins, 05=5mins, 06=6mins, 07=7mins, 08=8mins, 09=9mins, 10=10mins.
5.5. CTC-1052 SMS Remote Programming Command Table z If the SMS Keyword is set as PROG, and Access Code is set as 1111 (factory default).
CORRESPONDING DTMF CHARACTER COMMANDS 20# 21# 22# 23# 24# 31# ITEM Reporting method for all 4 Telephone numbers Reporting method for Telephone number 1 Reporting method for Telephone number 2 Reporting method for Telephone number 3 Reporting method for Telephone number 4 Ringer enable for incoming calls COMMAND FMATG FMAT1 FMAT2 FMAT3 FMAT4 ENRIN 32# Audible fault alert FAUTA 33# Help arrived signalling HELPA 34# Emergency button EMBUT 35# Silent mode SILMO 37# AC fault report A
CORRESPONDING DTMF CHARACTER COMMANDS ITEM 46# Follow-on & two-way period FOLTI 47# Off-set time OFFST 49# Supervision SUPPR 61# Check SIM card Pin code SIMPE 62# Input SIM card Pin code SIMPC COMMAND EXAMPLE & USAGE PROG 1111 FOLTI:02 To set the duration for follow-on & two-way voice communication period 01-10=1-10 minutes PROG 1111 OFFST:1 To set the off-set time 1=1 Hour, 2=2 Hours, 3=3 Hours 4=4 Hours, 5=8 Hours, 6=12 Hours PROG 1111 SUPPR:0 To set the supervision timer 0=Disable, 1=4
--- Access Point Name APNSR --- User name GPUSE --- Password GPASS --- Reset to factory default FTSET PROG 1111 APNSR:INTERNET To set/change the Access Point Name (APN server, 31 digits) PROG 1111 GPUSE:123 To set/change the user name Input 1 to 15 alphanumeric characters PROG 1111 GPASS:65536 To set/change the password Input 1 to 5 digits No APN No user name No password PROG 1111 FTSET:YyS 1.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.