User's Manual

9
z Factory default is set as (0) disable. Non-
emergency call will be reported to all of 4
Telephone Numbers.
z Please refer to section 4.1.2 for more
information.
z Non-emergency calls can be made both
when the Control Panel has a normal AC
power supply and when the Control
Panel’s AC power fails. When the Control
Panel has the AC failure condition, non-
emergency can be made by pressing and
hold the Reset button for 3 seconds. Then
the main unit will emit a beep every 2
seconds for 20 seconds until the Red LED
lights on, indicating the 3G module wakes
up to call out. Before the Red LED lights
on, you can press the Reset Button to
cancel calling.
<
<
N
N
O
O
T
T
E
E
>
>
) Command #07 can’t be used for GPRS
setting.
Command 10-14
Account Number Programming
z Commands (10-14) are used to set the
account number for the telephone numbers
used for Digital Reporting.
z Command (10): Set the same account
number for all telephone numbers.
z Command (11-14): Set the account
numbers for the 1
st
-4
th
Tel. numbers used
for Digital Reporting respectively.
z In (Function Selection) key in 4 or 6 digit
Account Number.
Command 20-24
Reporting Method
z Commands (20-24) are used to program
the Alarm reporting method for each Tel.
Number.
z Command (20): Program the same Alarm
Reporting Method for all
4 Tel. Numbers.
z Command (21-24): Program the alarm
reporting method for the 1
st
-4
th
Tel.
Numbers respectively.
z Available Options:
Method
Function
Selection
(0) Contact ID
(1) Scancom
Digital
Reporting
Method
(2) Tunstall
Speech
Method
(3)
Open Two-way
communication
SMS
Reporting
Method
(4) SMS (CID)
z (0), Contact ID, is set as factory default for
all 4 telephone Numbers.
<
<
N
N
O
O
T
T
E
E
>
>
) The latest Command (20-24) setting(s)
will overwrite any previously entered
setting(s).
) If any of Digital Reporting Methods
is selected:
Once alarm or emergency data is
successfully transmitted, CTC-1052
will automatically enter specific
Follow-On and/or Call Back Mode as
specified by Command (38).
) If Speech Method is selected:
After the dialing for alarm/emergency
trigger is successful, CTC-1052 opens
a two-way voice communication
between the Call Recipient and CTC-
1052 for 1-10 minutes (set by
Command #46).
If the Call Recipient needs more talk
time, they can press any keys except
9 on their phone set to add another 1-
10 minutes (set by Command #46).
To terminate the call, press (9) or
RESET BUTTON on CTC-1052.
During the Speech
period, CTC-1052
will emit two beeps via the telephone
handset to alert the call recipient the
remaining time of 20 & 10 secs.
During the Speech
period, if there is
no any DTMF command pressed, the
call will automatically hang-up and be
recorded as an unsuccessful call. It
will retry up to a max. of 4 times on
each Tel. Number accordingly.