User's Manual
12
automatically enter the Follow-On mode as
specified by Command (45).
Once Follow-On Mode is terminated, CTC-
1052 will automatically start a 5-minute
waiting period to auto answer any incoming
phone calls from the Monitoring Center.
<
<
N
N
O
O
T
T
E
E
>
>
) When the Monitoring Center calls back
within this 5-minute period, CTC-1052
auto-answers the call after the 1
st
-2
nd
ring and waits for proper Access Code
(default is 1111) entry, followed by the
(#) key within 15 secs.
Upon the correct Access Code is
received, CTC-1052 will then open a
Full-Duplex Communication to allow
the Call Recipient to speak to CTC-
1052 directly.
You can use DTMF command to
switch the communicating method.
Please refer to section 4.2. Alarm
Activation.
) The Access Code must be entered
within 15 secs. Otherwise, CTC-1052
will disconnect the call automatically.
) To terminate the call, press DTMF (9)
or RESET BUTTON on CTC-1052.
) If the 5-minute waiting period is up,
CTC-1052 will automatically exit this
waiting mode and return to idle mode.
) During the AC Power failure period,
Call-Back function is automatically
disabled.
Command 40
Set Access Code
z
The Access Code is used to enter
Programming Menu (locally or remotely),
and the Call-Back Function.
z It consists of 4 digits and has been set to
(1111) as factory default. Before you set
your own Access Code, (1111) must be
keyed in.
z To set a new Access code; enter the
desired (4-digit number)
in Function
Selection.
Command 42
Guard Time Delay
This command is deisgned for any
compitable sensor, except Fall Sensor
(fall detection).
z CTC-1052 can be programmed to delay
alarm reporting from (00) (instant reporting)
to (99) seconds.
z During this time period, a continuous series
of beeps will be emitted to alert user.
z If a false alarm is triggered, it can be
cancelled within the Guard Time Delay.
Function
Selection
Result
(00) INSTANT REPORTING
(01) - (99) DELAY
z Factory Default is (10), 10 SECONDS.
<
<
N
N
O
O
T
T
E
E
>
>
) Emergency alarm cannot be cancelled
after the Guard Time is elapsed.
) If an emergency alarm is triggered by
pressing the Active Button on Fall
sensor, the guard time delay time is
determined by Command 42, instead
of Command 66.
) The Guard Time Delay for Fall Sensor
fall detection is set by Command 66.
Command 43
Periodic Test Call
z
CTC-1052 can be programmed to make
test calls periodically from (00) (no test call)
to every (1) - (7) or 30 days:
Function Selection Result
(0) OFF
(1) - (7) 1 - 7 DAYS
(8) 30 DAYS
z Factory Default is set as (0), OFF.