User's Manual

16
) Echo volume varies depending on
adjustment of speaker volume and
microphone sensitivity. To minimize
the impact of echo, if you raise
speaker volume, please be sure to
lower microphone sensitivity, and vice
versa.
Command 64
Microphone Sensitivity Adjustment
z This function is used to adjust microphone
sensitivity. The microphone sensibility only
can be adjusted in the two-way mode.
z To set the microphone sensitivity with a
number, ranging 1 to 5. This value
represents the received sound source
range. The higher the value, the wider
range of sound source. Factory default is
set as (3).
z Please refer to programming command
table section for configuration.
<
<
N
N
O
O
T
T
E
E
>
>
) The sensitivity level in the Listen In or
Talk-Only mode is adjusted for the
best communication quality. It is fixed
and can not be changed.
) Echo volume varies depending on
adjustment of speaker volume and
microphone sensitivity. To minimize
the impact of echo, if you raise
speaker volume, please be sure to
lower microphone sensitivity, and vice
versa.
Command 66
Set Guard Time Delay Time for Fall
Sensor
z This command is used to set the guard
time delay time for fall sensor.
z CTC-1052 can be programmed to delay
alarm reporting (triggered by Fall Sensor)
from (00) (instant reporting) to (99)
seconds.
z During this time period, a continuous series
of beeps will be emitted to alert user.
z If a false alarm is triggered by Fall Sensor,
it can be cancelled within the Guard Time
Delay.
Function
Selection
Result
(00) INSTANT REPORTING
(01) - (99) DELAY
z Factory Default is (15), 15 SECONDS.
<
<
N
N
O
O
T
T
E
E
>
>
) This command is used if a fall is
detected.
) If an emergency alarm is triggered by
pressing the Active Button on Fall
sensor, the guard time delay time is
determined by Command 42, instad
of Command 66.
Command 80-84
Remove Devices
z CTC-1052 can be programmed to remove
ALL previously learnt devices by entering
(80) followed by (). The system will emit
an acknowledging beep over the phone for
the user.
z Command (81) is used to remove Pendant
# 1 (learnt-in by Command 91)
z Command (82) is used to remove Pendant
# 2 (learnt-in by Command 92).
z Command (83) is used to remove Silent
Wrist (learnt-in by Command 93).
z Command (84) is used to remove Other
Devices (learnt-in by Command 94).
<
<
N
N
O
O
T
T
E
E
>
>
) Power Switches are not to be removed
by any Command. They are to be
removed by clearning their own
memory. Please refer to the Power
Switch’s manual to proceed.
Command 91
Learn-In Pendant #1
<
<
N
N
O
O
T
T
E
E
>
>
) This command is not available in
Remote Programming Mode.
z Only one Pendant can be learnt into CTC-
1052 by using Command #91, including
WTR- Series or Fall Sensor.