User's Manual

18
removed from the system first.
) If one long beep is emitted
instead of 2 beeps, it indicates:
9 The device has already been
learnt-in.
9 Another device has been learnt-
in before.
<
<
N
N
O
O
T
T
E
E
>
>
) When CTC-1052 received the alarm
signal from the Silent Pendant, it will
not emit any warning beeps during
Reporting and Guard time period.
Command 94
Learn-In Device
<
<
N
N
O
O
T
T
E
E
>
>
) This command is not available in
Remote Programming Mode.
z Up to 7 devices can be learnt into CTC-
1052 by using Command #94.
z The available devices that can be learnt-in
Command #94
are:
9 PIR Sensor ----- PIR
9 Smoke Detector ---- SD
9 Carbon Monoxide ---- CO
9 Fixed Panic Button ---- PB
9 Wrist Transmitter ---- WTR
9 Pendant Transmitter ---- WTR
9 Water Sensor ---- WS
9 Fall Sensor
Step 1: Enter 94 + # on the phone set, then
a short beep will be heard via the
phone set
.
Step 2: Press the learn button on the
device within 20 secs.
) Learning can only be completed
within the signal reception range of
CTC-1052.
) If no signal is received within 20
sec, CTC-1052 will emit a long
beep and automatically returns to
Programming mode.
Step 3: CTC-1052 will emit 2 beeps to
indicate the device is learnt-in
successfully.
) Adding a Pendant for a second
time is prohibited unless it is
removed from the system first.
) If one long beep is emitted
instead of 2 beeps, it indicates:
9 The device has already been
learnt-in.
9 When an 8
th
device is attempted
to learn-in.
Step 4: Repeat steps 1-3 until all devices
are learnt-in.
<
<
N
N
O
O
T
T
E
E
>
>
) Adding a device for a second time is
prohibited unless it is removed from
the system first.
) Pressing the Test Button on Smoke
Detector or Carbon Monoxide will
cause Contro l Panel to send out an
Event Code 110(SD) or 162(CO). If the
Follow on or Call Back function is set
by Command 38, the Control Panel
will follow the preset parameter to
open the two-way communication.
Command 98
Factory Default Reset
z To Reset CTC-1052 to factory default
settings, enter (98) and then (#).
z After one short beep, continue by entering
(ÀÀ) and then end with another (#), one
beep will be heard for termination.
z Once the Factory Default Reset is
executed, all the programmed data is
returned to its default value and all the
devices that have been learnt-in are
removed. You have to do the programming
and learn-in the device one by one again.
Command 99
Exit Programming Mode
z Enter (99) and (#), after one short beep,
CTC-1052 exits the Programming Mode
and returns to idle mode.