User's Manual

20
4.1.2. Non-Emergency Speech Call
This function is only available when Command
#7 is programmed.
Normal AC Power Supply
Step 1. From Idle mode, press and hold the
RESET button for 3 seconds until
CTC-1052 emits a short beep.
Step 2. Release the button and one short
beep will sound. CTC-1052 dials the
phone number entered in Command
#7.
Step 3. If the dialing succeeds, CTC-1052 will
open a two-way voice communication
between the call recipient and CTC-
1052 for 30 minutes. The Red button
backlight will illuminate during the
communication.
<
<
N
N
O
O
T
T
E
E
>
>
) If the dialing fails, the Control Panel will
emit 5 beeps, indicating that the Control
Panel may have faults and it is not allowed
to use non-emergency call function.
Please make sure that the settings are
correct . Please note that the call will not
be retried.
Step 4. At the last 20 & 10 secs, CTC-1052
will emit a beep via the telephone
handset to alert the call recipient.
<
<
N
N
O
O
T
T
E
E
>
>
) 30-minute is allowed for each call and is
inextensible.
Step 5. Press DTMF 9 or Reset button, or
hang up to terminate the call. The Red
button backlight dims and CTC-1052
returns to idle mode.
AC Failure
Step 1. Press and hold the RESET button for
3 seconds until CTC-1052 emits a
beep every 2 second for 20 secods,
allowing 3G module to wake up and
dail out.
<
<
N
N
O
O
T
T
E
E
>
>
) Before the RED LED lights on, you can
press the Reset button to cancel calling.
Step 2. After 20 seconds, if the dialing
succeeds, CTC-1052 will open a two-
way voice communication between
the call recipient and CTC-1052 for 30
minutes. The Red button backlight will
illuminate during the communication.
<
<
N
N
O
O
T
T
E
E
>
>
) If the dialing fails, the Control Panel will
emit 5 beeps, indicating that the Control
Panel may have faults and it is not allowed
to use non-emergency call function.
Please make sure that the settings are
correct . Please note that the call will not
be retried.
Step 3. At the last 20 & 10 secs, CTC-1052
will emit a beep via the telephone
handset to alert the call recipient.
<
<
N
N
O
O
T
T
E
E
>
>
) 30-minute is allowed for each call and is
inextensible.
Step 4. Press DTMF 9 or Reset button, or
hang up to terminate the call. The Red
button backlight dims and CTC-1052
returns to idle mode.
4.1.3. AC Power Check Up
z If the AC Power failure is detected for 10
seconds or longer, the GREEN LED starts
to flash as a visual warning to the user. 3G
module will be then be powered down.
Thus, Remote Programming will become
unavailable. 3G module will be powered
up only at times of reporting
z Once the AC Power resumes, the GREEN
LED turns steady on again.
z If the AC Power failure lasts for an hour,
CTC-1052 will send an AC Failure
report
to the Monitoring Center.
z After the Power restoration lasts more
than one hour, CTC-1052 will report AC
Restore to the Monitoring Center.
z During the AC Power failure period, the
Call-Back function are automatically
disabled.
4.1.4. CTC-1052 Low Battery
z CTC-1052 continuously checks its own
Battery Condition 30 minutes after
powering up.
z When the battery low condition lasts for 4 -
6 mins
, CTC-1052 will report to the