User's Manual
21
Monitoring Center and the GREEN LED
flashes slowly.
z If Low Battery condition persists, CTC-
1052 will emit 2 short beeps every hour.
z After the battery voltage is restored and
lasts for 12 hours, CTC-1052 will send
Battery Restore
report to Monitoring
Center and the GREEN LED returns to
steady ON.
4.1.5. CTC-1052 Battery Disconnection
z CTC-1052 can detect the absence of
battery in the following cases:
Battery switch OFF
Battery not connected
Battery failure.
z When the battery disconnection lasts for
10-15 mins
, CTC-1052 will report to the
Monitoring Center and the GREEN LED
flashes slowly.
z If battery disconnection persists, CTC-
1052 will emit 2 short beeps every hour.
z The blinking status of RED LED can be
cleared by pressing the “RESET” button.
z After the battery is restored and it lasts for
10~15min, CTC-1052 will send Battery
Restore report to Monitoring Center and
the GREEN LED returns to steady ON.
4.1.6. Devices Low Battery
z When CTC-1052 receives a battery low
signal from a particular device, it will report
to the Monitoring Center and the GREEN
LED will flash rapidly until the fault
condition is cleared.
z In addition, CTC-1052 will emit 3 short
beeps every hour. Press the RESET
button on CTC-1052 will stop the warning
beeps.
z If any device Low Battery signal is
received again, the LED and warning
beeps will be performed accordingly.
Press the RESET
button again to silent
the warning beeps.
z After the faulty battery is replaced, CTC-
1052 will immediately send Battery
Restore report to the Monitoring Center for
that particular device.
4.1.7. Automatic Check-in Report =
Periodic Test Call
z When CTC-1052 is programmed to send a
periodical check-in report, CTC-1052 will
report to the Monitoring Center accordingly.
z The Periodic-Check-in Timer will be reset
whenever Programming Mode is entered.
4.1.8. Mobility Timer
z In order to check the user’s well being, a
Mobility Timer can be set by using
Command #44
.
z If Mobility Timer is set as Enable, a
counting down period starts from:
Immediately after powering up CTC-
1052
Exit Programming Mode
z After the pre-set Timer expires, CTC-1052
will emit a beep at every 5 minutes to
notify the user for 30 minutes.
z When the Mobility timer is not reset after
30 minutes, CTC-1052 will send a
Mobility Timer Expired report to the
Monitoring Center.
z After CTC-1052 sends a Mobility Timer
Expired Report, but the Mobility timer still
not be reset, when reaching next pre-set
time, the CTC-1052 will emit a beep at
every 5 minutes to notify the user for 30
minutes. Yet, if no reset action after 30
minutes, the panel will send another
Mobility Timer Expired report to the
Monitoring center and the step will
repeatly until Mobility timer is reset.
z Mobility Timer can be reset by pressing
RESET
button once on CTC-1052 or
whenever a movement is detected by PIR
Detector.
z To disable the Mobility Timer function:
Set Command #44
to 00 (Disable), or,
Press and hold the RESET
button on
CTC-1052 for 16 seconds or longer.
<
<
N
N
O
O
T
T
E
E
>
>
) If no movement is detected during preset
mobility time, CTC-1052 will send a CID
event code 641 with a fixed zone number
071 regardless of the zones the triggered