z The first alarm reporting priority is
GPRS Reporting Method.
Confirmation Beeps
z Once Guard Time Delay expires,
CTC-1052 will summon help based on
the programmed reporting method. A
continuous confirmation beeping
sound (about 1 secs per beep) will be
heard after CTC-1052 dials out, to
inform you that the call is in progress
(regardlss of Digital or Speech
Reporting Method).
z Confirmation beeps will be heard in
the following situations:
After CTC-1052 dials out to summom
help until kiss off (for Digital
Reporting Method)
After CTC-1052 dials out to summom
help until the call is answered (for
Speech Reporting Method)
When first reporting failed, and CTC-
1052 retries
z Once the first reporting succeeded,
and CTC-1052 is in progress of back-
up reporting, the confirmation beeps
will not be heard.
GPRS Reporting Method
z It is required to use SMS Remote
Programming to set Access Point
Name, IP Address, Port Number,
GPRS/IP Account Number, User
Name, and Password before GPRS
Reporting Method becomes effective.
z Access Point Name (APN): the
name of an access point for GPRS.
Please inquire your SIM card service
provider for your APN.
z IP Address: Central Monitoring
Station server IP
z Port Number: Central Monitoring
Station server port number
z GPRS/IP Account Number: your
account number, as set in Digital
Reporting Method (refer to section 3.2.
Programming Your 1052: Command
10-14)
z User Name: offered by your SIM card
service provider. Please inquire your
service provider for your GPRS
username. If no username is required,
you may skip this step.
z Password: offered by your SIM card
service provider. Please inquire your
service provider for your GPRS
password. If no Password is required,
you may skip this step.
z To disable GPRS Reporting Method:
by removing the IP address, GPRS
reporting becomes ineffective.
Proceed to SMS Remote
Programming and send in this format:
PROG 1111 TCIP1:
Where:
PROG = SMS Keyword
1111 = Access Code
TCIP1 = SMS command for IP Address (no
input value means deletion of characters)
Digital Reporting Method
z After the alarm reporting is
successfully received by the
Monitoring Center, CTC-1052 will then
follow the choice of Command #38, to
enter Follow-On and/or Call-Back
mode.
z If Command #38
is set as Call-Back
(1
) or Follow-On & Call-Back (2) after
alarm reporting, it will then wait 5 mins
for Monitoring Center Personnel to
call-back after reporting.
z When the Monitoring Center calls
back within this 5-minute period, CTC-
1052 auto-answers the call after the
1st -2nd ring and waits for proper
Access Code (default is 1111
) entry
followed by the (#) key within 15 secs.
Please enter Access Code in normal
operation speed.
z Upon the correct Access Code
received, CTC-1052 will then open a
Full-Duplex Communication to allow
the Call Recipient to speak to CTC-
1052 directly. You can also use the
following DTMF command to switch
the speech mode.
Enter (1) to TALK ONLY
Enter (2) to open TWO-WAY VOICE