User's Manual

25
Please note that when a particular
DTMF key is pressed, its designed
shortcut function will be executed &
the communication time will be
extended at the same time.
<
<
N
N
O
O
T
T
E
E
>
>
) Please note that if you wish to enable a
designed shortcut function, please press
DTMF keys over 1 second to enable the
function you desire.
) If the levels of speaker volume and
microphone sensitivity can only be
adjusted in the two-way communication
mode, the adjusted value will be kept at
next use.
3. TUNSTALL FORMAT:
Enter (C) to TALK ONLY
Enter () to LISTEN-IN ONLY
Enter (3) to open TWO-WAY VOICE
COMMUNICATION
End a Call: enter (#) to HANG UP or
put the handset back into the base
cradle.
Enter (7) to Speaker Volume Control
and then press (6) or (4) to increase
or decrease the levels of speaker
volume in the “Two-Way”
ommunication mode.
Enter (8) to Microphone Sensitivity
Control and then press (6) or (4) to
increase or decrease the levels of
microphone sensitivity in the “Two-
Way” communication mode.
Press any DTMF key,
except the
designed “hang-up” key (#), to add
another preset communication time.
Please note that when a particular
DTMF key is pressed, its designed
shortcut function will be executed &
the communication time will be
extended at the same time.
<
<
N
N
O
O
T
T
E
E
>
>
) Please note that if you wish to enable a
designed shortcut function, please press
DTMF keys over 1 second to enable the
function you desire.
) If the levels of speaker volume and
microphone sensitivity can only be
adjusted in the two-way communication
mode, the adjusted value will be kept at
next use.
) The allowable time duration for Follow-On
Period is set by Command #46
(1-10
mins).
z During Two-way Voice Communication, at
20 & 10 seconds before the Follow-On
period expires, CTC-1052 will emit two
beeps to alert both the user and the
Monitoring Center Personnel.
z To extend the conversation, the Monitoring
Center personnel can press the DTMF
command again to add another 1-10 mins.
z Voice Communication can be terminated
by the following:
DTMF Commands:
Contact ID: 9
Scancom: 5
Tunstall: #
The RESET button is pressed.
Automatically hangs up after the
Follow-On Period expires.
z Help Arrived Signaling
This function is only available for the digital
Contact ID reporting method, and when
Help Arrive Signaling (Command #33) is set
to enable.
Once the Follow-On Period or Call-
back is completed, CTC-1052 will
start counting down the 15-min Help
Arrived Timer. The HELP
button
starts flashing.
By pressing the RESET
button, CTC-
1052 will report to the Monitoring
Center that help has arrived. The
HELP
button stops flashing and
return to normal backlight.
If the RESET
button is not pressed
within 15 mins, CTC-1052 will send
another Help Call report again to
inform the Monitoring Center that no
help has arrived.
CTC-1052 will then enter the 15 mins
waiting period again. If RESET
button is still not pressed, CTC-1052
will exit reporting mode and return to
Idle Mode.