User's Manual
26
Speech Reporting Method
z If Speech Reporting Method is selected,
after dialing, CTC-1052 will open a two-
way voice communication between the
Call Recipient and CTC-1052 for 1-10
minutes (set by Command #46
).
z At 20 & 10 seconds before the time period
expires, CTC-1052 will emit two beeps via
the telephone handset to alert the user.
z If the Call Recipient needs more talk time,
they can press any keys except 9
on their
phone set to add another 1-10 minutes
(set by Command 46).
z To terminate the call, press either (DTMF
9) or RESET button on CTC-1052.
z During the Speech
period, if there is no
any DTMF command pressed, the call will
automatically hang-up and be recorded as
an unsuccessful call. It will retry a max of
4 times on each Tel. Number accordingly.
Call Sequence
The call sequence is followed by Tel.
#1, Tel. #2, Tel. #3 to Tel. #4. It is
recommended to set digital reporting
method in first priority for immediate
help.
If either Digital Alarm reporting or
Speech Alarm reporting is set, with
anyone answered successfully, the
call sequence will be terminated
automatically.
If both Digital and Speech Alarm
reporting are set, the reporting call
sequence will
only be terminated
once one Digital reporting (any of CID,
Scancom or Tunstall protocols) and
one Speech reporting are answered
successfully.
There is a calling pause between
each call. For different Tel. Numbers,
the pause is set as 5 secs, and for
same Tel. Number, it is set as 62 secs.
Retry Method:
Retry Circle: Each Tel. Phone number can
be retried up to 5 times alternative; and
max. 15 calls will be retried. During the
retry period, the Red LED still stays on
steadily, while the Red Help Button
backlight dims.
In the retry circle, if any digital, voice
message, or speech reporting fails, CTC-
1052 makes a 10-min pause, then starts
another 15-call retry circle, followed by
another 10-min pause. This cycle repeats
until all reporting is/are answered
successfully.
During the 10-min pause, CTC-1052
returns to normal mode with Red LED on:
Press the Green reset button to
terminate the reporting.
If new event happens, CTC-1052
starts the reporting immediately.
4.3 Walk Test (Range Test)
Put CTC-1052 in Learning Mode to determine
the operation range of the devices.
Step 1. From Idle mode, press and hold the
RESET button for 6 seconds.
Step 2. Once pressed, a button beep sound
will be heard. CTC-1052 will emit one
short beep at 3 sec., then a double
beep when it reaches 6 sec.
Step 3. Release the button after you heard the
double beep
. Then, a short beep will
be heard indicating CTC-1052 is now
in Learning Mode. The RED LED
begins to flash.
Step 4. Move the device to your desirable
location in the house, and press the
TEST button to observe the range for
its operation.
Step 5. If CTC-1052 responds with one long
beep, then the particular device is
within the operation range.
Step 6. To exit Learning Mode, press both
RESET
& HELP buttons
simultaneously.
Or, CTC-1052 will exit Learning mode
automatically after 5 mins of inactivity.
4.4 Global Test
z Global Test is used to test if the complete
system is working properly.
To do the Global Test:
Step 1. Press the RESET