User's Manual
27
Step 2. Within 5 secs, press Pendant
button.
Step 3. CTC-1052 will emit a short beep
and report to Monitoring Center.
4.5 Factory Reset
CTC-1052 will clear all programmed
parameters by the following sequence:
Step 1. Unplug the power cord from the DC
Jack.
Step 2. Remove the Battery Switch rubber
cap.
Step 3. Use a pen or screw-driver to slide the
Battery Switch to OFF
position (or the
opposite direction of the ON marking)
Step 4. Plug the power cord into the DC jack
while holding down both the HELP
&
RESET
buttons, until one long beep
is heard, indicating that the Factory
Reset is successful.
Step 6. Release both buttons
Step 7. Slide the Battery Switch back to ON
position again.
Step 8. Replace the Battery Switch rubber
cap.
<
<
N
N
O
O
T
T
E
E
>
>
) Once the Fatory Reset is executed, all
the programmed data is returned to its
default value and all the devices that
have been learnt-in are removed. You
will have to do the programming and
learn-in the devices one-by-one again.
5. Appendix
5.1. CID Event Code
z 100 - Panel emergency
When Red HELP button is pressed.
z 101 - Personal emergency
When the Wrist Transmitter /
Emergency Pendant (WTR) or Fall
Sensor is pressed.
z 102 –Inactivity
If no sudden movement within 10
seconds after fall detection, an
inactivity code will be sent to Central
Monitoring Station.
z 110 - Smoke emergency
When the Smoke Detector (SD) is
triggered.
When the Test Button of the Smoke
Detector (SD) is pressed.
z 120 –Fall emergency
When Fall Sensor is triggered
z 147 - Sensor Supervisory Failure
When CTC-1052 is unable to receive
the signal transmitted from the Wrist
Transmitter for a pre-set period by
Command #49, the Green LED
flashes every 2 secs.
z 154 - Water emergency
When Water Sensor (WS) is triggered
z 162 - Carbon Monoxide emergency
When Carbon Monoxide Detector
(CO) is triggered
When the Test Button of Carbon
Monoxide Detector (CO) is pressed.
z 301 - Panel AC Failure
When AC power fails for more than 10
sec, the Green LED flashes every sec
with a beep every 30 secs.
z 302 - Panel Low battery
When CTC-1052 is under Low Battery
status, the Green LED flashes every 2
secs with 2 short beeps every hour.
z 311 - Panel Battery Disconnection
When CTC-1052 is under Battery Not
Connected status, the Green LED