User's Manual
28
1052-QT-DT35A will automatically hang up the line and start a 5-minute waiting period to auto
answer any incoming phone calls from the Monitoring Center.
- When selected as “Follow-On & Call-Back”, after a successful reporting to the Monitoring
Center, CTC-1052-QT-DT35A will automatically enter specific Follow-On mode. Once Follow-
On Mode is terminated, CTC-1052-QT-DT35A will automatically start a 5-minute waiting
period to auto answer any incoming phone calls from the Monitoring Center.
40# Set Access Code:
- The Access Code is used to enter Programming Menu, and the Call-Back Function. It consists
of 4 digits and has been set to (8744) as factory default.
- To set a new Access code, enter the desired (4-digit number) in this field.
41# Auto Answer for Remote Programming:
- CTC-1052-QT-DT35A can be programmed to auto answer incoming phone calls after a pre-set
number of rings have been reached. The number of rings ranges from (01) to (09) rings.
- When set as “None”, CTC-1052-QT-DT35A will not auto-answer the call by ring count. If
Remote programming is required, you will need to call CTC-1052-QT-DT35A twice.
42# Guard Time Delay:
- Guard Time Delay is a time period programmed to delay alarm reporting. If a false alarm is
raised, it can be cancelled within this Guard Time Delay time.
- Guard Time Delay is designed for any compatible sensor, except Fall Sensor (fall detection).
The delay time can range from (00) (instant reporting) to (99) seconds.
- Emergency alarms activated by Smoke Detectors (SD), Carbon Monoxide Detectors (CO),
Carbon Dioxide Detector (CO2), Temperature Sensor (TS), and Water Sensors (WS) do not
have Guard Time Delay and will be reported immediately.
- The Guard Time Delay time from pressing the Active Button on a Fall sensor is determined by
Command #42 Guard Time Delay, instead of Command #66 Guard Time Delay Time for Fall
Sensor.
- The Guard Time Delay time from Fall detection is determined by Command #66 Guard Time
Delay Time for Fall Sensor, instead of Command #42 Guard Time Delay.
43# Periodic Test Call:
- CTC-1052-QT-DT35A can be programmed to make test calls periodically (every 0 – 7 days, 0-
23 hours, and 0-59 mins). Whenever programming mode is accessed, CTC-1052-QT-DT35A
will reset the Periodic Test Call timer.
- Whe this function is disabled (0 day, 0 hour, 0 min), CTC-1052-QT-DT35A will not make
periodic test calls.
44# Mobility Timer:
- This function monitors user movement around the premises and sends an inactivity report to
the Monitoring Center if the user fails to reset the inactivity timer.
- Mobility Timer can be selected as 1-36 HR count down periods, or it can be disabled.
- The Mobility Timer counting down can be reset by either pressing the RESET button on CTC-
1052-QT-DT35A, or movement detected by PIR Detector.
46# Two way Period:
- This is used to program the allowable time duration for Two-way voice communication period
(Speech mode). It can be set from 1 to 10 minutes.