47# Off-Set Time:
- After power is supplied or re-supplied to the Control Panel, the first auto check-in report will be
made according to Offset Period setting. This is used to test whether the CMS is able to
receive the report from the Panel accurately.
- After this test report is sent, the Control Panel will then send reports at regular interval based
on the setting of the Periodic Test Call.
49# Supervision:
- This option is used to enable system Supervision function. Once enabled, CTC-1052-QT-
DT35A will be able to receive the check-in signals from Wrist Pendants (WTR) to indicate their
proper functioning.
- When the supervisory timer expires and no supervision signal is received from WTR, CTC-
1052-QT-DT35A will send a Supervisory Failure report.
53# Voice Prompt Language:
- Select the voice prompt language for CTC-1052-QT-DT35A. Available options include English,
Arabic, Spanish, Russian, and beep only.
54# Fall Sensor Sensitivity
- Select the Fall Sensor 3 Sensitivity. There are 5 sensitivity levels for selection. 1=Lowest
Sensitivity, 5=Highest Sensitivity
66# Guard Time Delay for Fall Sensor:
- The Guard Time for Fall Sensor’s fall detection function is set separately from regular Guard
Time.
- 1052-QT-DT35A can be programmed to delay alarm reporting (triggered by Fall detection) from
(00) (instant reporting) to (99) seconds.
- During this period, a continuous series of beeps will be emitted to alert user. If a false alarm is
triggered by Fall Sensor, it can be cancelled within the Guard Time Delay.
- If an emergency alarm is triggered by pressing the Active Button on Fall Sensor, the guard time
delay time is determined by Command #42 Guard Time Delay, instead of Command #66
Guard Time Delay Time for Fall Sensor.
76# Call Progress Tone:
- When turned on, you will hear a dialing tone from the speaker indicating the status of phone
calls.
- When this function is set to OFF, you will not hear the dialing tone of phone calls.
- This function will be disabled if Silent Mode (Command 35) is enabled, or alarm activation is
made from a Silent Device (learnt using Command #93).
77# Speech Report ACK
- When speech report is set to (0), press any DTMF key for panel to regard speech reporting
successful.
- When speech reporting is set to (1), off-hook phone for panel to regard speech reporting
successful.
- Factory default is (0), Any DTMF.