User's Manual
40
<EXAMPLE>
With the phone number 0987654321, the format
should either INCLUDE or EXCLUDE Contry
Code, which is “886” for Taiwan as below:
Step 4. Remove the SIM card from the Mobile
phone and insert it back into SIM Card
holder on Panel.
A. If the Phone Number Format EXCLUDES
Country Code, please skip this section.
B. If the Phone Number Format INCLUDES
Country Code, please proceed to SMS
Remote Program and send in this format:
“PROG 8744 REPLA:886&0”
Where:
PROG = SMS Keyword
8744 = Access Code
REPLA = SMS command for Country Code
886 = number to be replaced
0 = number to substitute
After this is completed, Country Code “886”
will be replaced by “0”.
5.1.9. Temperature
1052-QT-DT35A has built-in temperature
sensor or it can learn in temperature
sensor, which allows the Panel to report to
CMS when high or low temperature is
detected.
When temperature reaches or rises above
the High Temperature threshold (default
95°F/35°C), the panel will send High
Temperature report to CMS.
After High Temperature report, if
temperature drops under 95°F/35°C, the
panel will send High Temperature Restore
report to CMS.
When temperature reaches or drops below
the Low Temperature threshold (default
47°F/8.3°C), the panel will report Low
Temperature Alarm to CMS.
After Low Temperature report, if
temperature rises above 47°F/8.3°C, the
panel will send Low Temperature Restore
report to CMS.
5.2. Alarm Activation
When an alarm is triggered, CTC-1052-QT-
DT35A will enter the Guard Time Delay
period (see Command 42). The Help
Button red backlight will turn on.
During the Guard Time period,
pressing the Reset Button on CTC-
1052-QT-DT35A will stop alarm
reporting and return to Idle Mode.
If the Guard Time Delay is set as 00,
CTC-1052-QT-DT35A will dial
immediately.
An alarm report can be canceled anytime
by pressing the Reset Button on CTC-
1052-QT-DT35A.
Call Progress Tone
Once Guard Time Delay expires, CTC-
1052-QT-DT35A will summon help based
on the programmed reporting method. If
Call Progress Tone is set as On, dailing
tones will be heard once the CTC-1052-QT-
DT35A goes off-hook.
Guard Time Delay
Guard Time Delay time is a time period
programmed to delay alarm reporting (by
command #42). If a false alarm is raised,
the user can cancel the alarm before the
Control Panel starts reporting.
Emergency alarms activated by Smoke
Detectors (SD), Carbon Monoxide
Detectors (CO), Carbon Dioxide Detector
(CO2), Temperature Sensor (TS), and
Water Sensors (WS) do not have Guard
Time Delay and will be reported
immediately. CTC-1052-QT-DT35A will play
voice prompt “Fire Alarm,” “Carbon
Monoxide Alarm,” “Water Leak Alarm” to
inform the user of the alarm at hand.
During this time period, Control Panel will
play a voice prompt “Emergency call was
pressed” to alert the user(s).
<NOTE>
INCLUDE
Country Code
+886987654321
EXCLUDE
Country Code
0987654321