User's Manual

49
6.3. CTC-1052-QT-DT35A Voice Prompts
The Control Panel plays voice prompts on important occasions to report its condition or remind you to
take a specific action. Information on voice prompts is provided in the chart below.
Voice Prompt Condition
Release the Button
Played once after long pressing (6 seconds) the Learn Button on the
Control Panel to enter learning mode.
Ready to Learn Sensor Played once after entering learning mode
Press Sensor Button
Played once if no action within 10 seconds after “Ready to learn
sensor” prompt. This prompt will repeat two times if no action.
Press the Button to Exit
Played once if no action after second “Press Sensor Button” prompt.
This prompt will be repeated three times if no action continues.
{Sensor Type} Learned
Played in learning mode, when the button on the device or sensor is
pressed
We are now in normal operation mode
Played once when the Learn Button was pressed to exit learning
mode.
Played once after five minutes of no action in learning mode. The
Control Panel as returned to idle mode.
Emergency Button/Panic Button Played once when the sensor has been learnt into the Control Panel
Smoke Detector Played once when the sensor has been learnt into the Control Panel
Heat Detector Played once when the sensor has been learnt into the Control Panel
Motion Sensor Played once when the sensor has been learnt into the Control Panel
Fall Sensor Played once when the sensor has been learnt into the Control Panel
Carbon Monoxide Detector Played once when the sensor has been learnt into the Control Panel
Door Sensor Played once when the sensor has been learnt into the Control Panel
Water Leak Sensor Played once when the sensor has been learnt into the Control Panel
Emergency call was pressed
Played once after pressing the Help Button on the Control Panel,
Active Button on Panic Button, WTR, Fall Sensor or DECT device.
Emergency call in progress Played once every 2-3 seconds during guard time
Emergency call cancelled Played twice when the reset button is pressed during guard time
A fall has been detected Played once when a fall sensor is triggered.
Fall detection has restored,
cancelling help call
Played after the reception of a fall sensor’s cancel code
Water Leak Alarm Played when water has been detected by Water Leakage Detector
Fire Alarm Played when fire has been detected by Fire Alarm
Carbon Monoxide Alarm
Played when specific levels of carbon monoxide is detected by
Carbon Monoxide Detector
Power failure, check power cord Played twice when a power failure takes place
Power restored Played once when power is restored
Inactivity timer expiring, please reset
Played once every 5 minutes during Warning Period (default 30
minutes). After Warning Period, the Control Panel will start reporting
to Monitoring Centre
Inactivity timer reset Played once when the inactivity timer has been reset
Searching for Cell Signal Played when cellular module is activated
System Ready Played when GSM registration is successful
GSM Signal
(One, Two, Three, Four, Five)
Played when the Learn Button is pressed to exit Learning Mode to
announce GSM RSSI value.
Test Call being placed Played when the test button is pressed.