Table of Contents 1. Application Overview _______________________________________________________ 1 1.1. Identifying The Parts ____________________________________________________________ 1 1.2. The Power Supply ______________________________________________________________ 2 1.3. Insert GPRS/GSM SIM Card ______________________________________________________ 3 1.4. How to install the Control Panel __________________________________________________ 3 1.5.
4.6. Factory Reset__________________________________________________________________ 29 5. Appendix __________________________________________________________________ 29 5.1. CID Event Code ________________________________________________________________ 29 5.2. Tunstall Event Code____________________________________________________________ 30 5.3. Scancom Event Code __________________________________________________________ 30 5.4.
1. Application Overview RED HELP BUTTON (with backlight) — Back-lit disigned for easy access at night 1.1. Identifying The Parts — Backlight illuminates when off-hook TOP VIEW — Backlight flashes during the waiting period until help arrives 5 Microphone 6 Speaker REAR VIEW 1 GREEN LED — ON: AC Power is ON. — FLASH every second: AC Power failure — FLASH every 2 seconds: Panel or Device Low battery 7 — This slot is for inserting a SIM card.
Battery Switch 1.2. The Power Supply Local Programming Telephone Unit Input z An AC power adapter is required to connect to a wall outlet. Be sure only to use an adapter with the appropriate AC voltage rating to prevent component damage. A DC 12V output and 2A switching power is generally used to power CTC-1052RV. z In addition to the adapter, there is a rechargeable battery inside CTC-1052RV, which serves as a back-up in case of a power failure. z The battery used is a Ni-Cd 7.
1.3. Insert GPRS/GSM SIM Card 1.4. How to install the Control Panel CTC-1052RV Panel features built-in GPRS/GSM communication facility to report to the Monitoring Station. Locating a suitable position for the Control Panel z To Insert SIM card: z The Control Panel requires main power and a constant GPRS/GSM reception. z The Control Panel should be easily accessible. z The Control Panel should not be placed in a damp location, such as a bathroom.
2. Learn-in the Devices There are two methods to learn in devices: local learning and command learning. Total 10 sensors (including one talking pendant, WTRV or WTRVS) are allowed to be learnt into the system. And only one WTRV/ WTRVS can be learnt into the system. 5. Command 93 is designed to learn in WTR- Series or Fall Sensor only for silent reporitng. 6.
5. Press and hold the RESET button on CTC-1052RV for 20 seconds and release button until you hear two beeps, followed by a long beep. For Talking Pendant (WTRV/ WTRVS) 1. Press and hold the RESET button of CTC1052RV for 6 seconds until you hear the double beep and followed by a long beep. 2. The RED LED starts flashing. CTC1052RV is now in the learning mode. 3. Press and hold the WTRV/ WTRVS button for 5 seconds until you hear a long beep. The WTRV/ WTRVS’s Green LED turn to RED. 4.
3. System Configuration 3.1.2. CTC-835 Programmer 3.1. Entering Programming Mode CTC-835 is a powerful programming tool (sold separetely) that features a built-in keypad and LCD display to help you to program the medical alarm panels effeciently and conveniently. It also features Once-for-All Uploading, which allows you program on a computer via the supplied Pilot software and you can then upload all the settings to the medical alarm panel simultaneously with a single mouse click.
On the programming phone set: Command 01-04 Short beep: Command succeeded Telephone Number Programming Long beep: Command failed z Used to program the 1st - 4th Tel. numbers respectively. 4. Function Selection = According to different Command you will have different entering in this part, e.g. Tel. Number, Account number, etc. z To program the 1st Tel. number: enter (01) followed by (#). After one short beep, enter (telephone number) followed by (#).
z Available Key-in options: Tel. Number / IP Address Function Selection Sequence 1st Tel. # (1) 2nd Tel. # (2) 3rd Tel. # (3) 4th Tel. # (4) 5th GPRS1 # (5) 6th GPRS2 # (6) 1st & 2nd Tel. #s (12) 1st & 3rd Tel. #s (13) 1st & 4th Tel. #s (14) 1st Tel & 5th GPRS. #s (15) st th 1 Tel & 6 GPRS. #s (16) 2nd & 3rd Tel. #s (23) 2nd & 4th Tel. #s (24) 2nd Tel & 5th GPRS. #s (25) 2nd Tel & 6th GPRS. #s (26) 3rd & 4th Tel. #s (34) 3rd Tel & 5th GPRS. #s (35) 3rd Tel & 6th GPRS.
z Please refer to section 4.1.2 for more Method information. z When the Control Panel has the AC failure Speech Method condition, non-emergency can be made by pressing and hold the Reset button for 3 seconds. Then the main unit will emit a beep every 2 seconds for 20 seconds until the Red LED lights on, indicating the GSM module wakes up to call out. Before the Red LED lights on, you can press the Reset Button to cancel calling.
when alarm can’t go through in digital reporting method. Once alarm or emergency data is successfully transmitted, the CTC-1052RV will automatically send out a SMS (CID) Message. OFF (0) (No Warning Beep) ON (1) (With Warning Beep) z Factory Default is set as (0), OFF. Command 31 z The fault situation includes Low Battery Fault (for both CTC-1052RV and Devices) and AC Failure.
Command 34 Command 37 Emergency Button Enable AC Fault Report z The RED HELP BUTTON can be enabled z The CTC-1052RV can be programmed to or disabled to send an Emergency alarm report: send a Fault Report when an AC power failure is detected. Function Selection (0) (1) Function Selection Result (0) OFF Result OFF (Send No Report) (Deactive) (1) ON (Active) z z Factory Default is set as (1), ON. ON (Send Report) Factory Default is set as (1), ON.
after a successful alam reporting (triggered by pressing the Help button on the Medical Panel) to the Monitoring Center, CTC1052RV will automatically hang up the line and start a 5-minute waiting period to auto answer any incoming phone calls from the Monitoring Center. The Monitoring Center personnel should enter an authorized access code (default: 1111), followed by (#) to set up the two way communication between CTC-1052RV and the Monitoring Center. section 4.2. Alarm Activation.
(00) INSTANT REPORTING (01) - (99) DELAY z This will disable or enable the Inactivity Timer with selectable count down periods. Options are: z Factory Default is (10), 10 SECONDS. ) Emergency alarm cannot be cancelled after the Guard Time is elapsed. ) The Guard Time Delay for Fall Sensor is set by Command 66. Command 66 is used if a fall is detected.
Personnel. Command 45 Follow-On Mode Choice z This Command is only available for Digital reporting with Command #38 set as (0) or (2). z It is used to select the Follow-On Choice for CTC-1052RV after it has made a report to the Monitoring Center.
according to the setting of Command 43 - Test call. Function Selection Result (1) 1 Hour (2) 2 Hour (3) (4) 3 Hour 4 Hour (5) 8 Hour (6) 12Hour (7) 10 Days z Factory default is set as (0) Disable. No code is sent to Monitoring Center. z When the supervisory timer expires and no supervision signal is received from WTR-, the supervisory alarm reporting will be made. z The reporting method for supervisory alarm is the same as the emergency alarm.
communication channels, different parameters. Command 61 Check SIM Card PIN Code This option is used to check SIM card PIN Code. Function Selection (0) (1) please Function Selection Result (2) Two-way Result set z To set speaker volume in two-way modes, OFF the sequence is: (Disable) Communication Channel DTMF Speaker Volume ON (Enable) 2 * 1 to 5 z Factory default is set as (0) OFF.
z To set the microphone sensitivity with a number, ranging 1 to 5. This value represents the received sound source range. The higher the value, the wider range of sound source. Factory default is set as (3). z Please refer to programming command ) If an emergency alarm is triggered by pressing the Active Button on Fall sensor, the guard time delay time is restricted to Command 42, rather than Command 66. ) The Guard Time Delay for Fall Sensor is set by Command 66.
a short beep will be heard via the phone set. sec, CTC-1052RV will emit a long beep and automatically returns to Programming mode. Step 2: Press the Pendant Button within 20 secs. ) ) Step 3: CTC-1052RV will emit 2 beeps to indicate that Pendant #2 is learnt-in successfully. Learning can only be completed within the signal reception range of CTC-1052RV. If no signal is received within 20 sec, CTC-1052RV will emit a long beep and automatically returns to Programming mode.
9 9 Another device has been learntin before. 9 ) When CTC-1052RV received the alarm signal from the Silent Pendant, it will not emit any warning beeps during Reporting and Guard time period. Step 4: Repeat steps 1-3 until all devices are learnt-in. ) Adding a device for a second time is prohibited unless it is removed from the system first. ) WTRV is not able to learn-in under this command. Command 94 Learn-In Device ) The device has already been learnt-in.
Step 2: Enter the SMS keyword (default is PROG). 4. Operation Step 3: Enter a space. 4.1. Idle Mode Step 4: Enter the access code (default is 1111 as defined by Command 40). When the system is in Idle Mode, CTC1052RV is ready to execute the following functions: Step 5: Enter a space. Step 6: Enter the programming command. 4.1.1. Answering Incoming Phone Calls Step 7: Editing is complete; you may send to the Control Panel.
) If the two way communication is setup between WTRV/ WTRVS and the emergency call recipient, the levels of speaker volume and microphone sensitivity can not be adjusted. ) Before the RED LED lights on, you can press the Reset button to cancel calling. This function is only available when Command #7 is programmed. Step 2. After 20 seconds, if the dialing succeeds, CTC-1052RV will open a two-way voice communication between the call recipient and CTC1052RV Pro for 30 minutes.
beep at every 5 minutes to notify the user for 30 minutes. Yet, if no reset action after 30 minutes, the panel will send another Mobility Timer Expired report to the Monitoring center and the step will repeatly until Mobility timer is reset. 4.1.4. CTC-1052RV Low Battery z CTC-1052RV continuously checks its own Battery Condition 30 minutes after powering up. z When the battery low condition lasts for 4 6 mins, CTC-1052RV will report to the Monitoring Center and the GREEN LED flashes slowly.
4.2. Alarm Activation 4.1.9. Country Code z The Phone Number Format for each SIM card may vary between different Telecom companies. Thus, you can either check with your Telecom provider or follow the steps described below to check the correct format. Step 1: Remove the SIM card from SIM card holder on the Panel, and insert it into a workable mobile phone. Step 2: Power on the mobile phone and send a test SMS message to another mobile telephone number.
z Access Point Name (APN): the name of an access point for GPRS. Please inquire your SIM card service provider for your APN. z IP Address: Central Station server IP z Port Number: Central Monitoring Station server port number z GPRS/IP Account Number: your account number, as set in Digital Reporting Method (refer to section 3.2. Programming Your 1052: Command 10-14) z User Name: offered by your SIM card service provider. Please inquire your service provider for your GPRS username.
z z between WTRV/ WTRVS and the emergency call recipient, the levels of speaker volume and microphone sensitivity can not be adjusted. If an alarm is successfully reported, after the Monitoring Center calls back within this 5-minute period, CTC1052RV auto-answers the call after the 1st -2nd ring and waits for proper Access Code (default is 1111) entry followed by the (#) key within 15 secs. Please enter Access Code in normal operation speed.
function you desire. shortcut function will be executed & the communication time will be extended at the same time. ) If the levels of speaker volume and microphone are adjusted in the two-way communication mode, the adjusted value will be restored. ) If the two way communication is setup between WTRV/ WTRVS and the emergency call recipient,, the levels of speaker volume and microphone sensitivity can not be adjusted.
mins waiting period again. If RESET button is still not pressed, CTC1052RV will exit reporting mode and return to Idle Mode. microphone are adjusted in the two-way communication mode, the adjusted value will be restored. ) If the two way communication is setup between WTRV/ WTRVS and the emergency call recipient, the levels of speaker volume and microphone sensitivity can not be adjusted.
If both Digital and Speech Alarm reporting are set, the reporting call sequence will only be terminated once one Digital reporting (any of CID, Scancom or Tunstall protocols) and one Speech reporting are answered successfully. 4.4. Walk Test (Range Test) Put CTC-1052RV in Learning Mode to determine the operation range of the devices. Step 1. From Idle mode, press and hold the RESET button for 6 seconds. Step 2. Once pressed, a button beep sound will be heard.
Center. 5. Appendix ) 5.1. CID Event Code This function is for WTR- Series only, not for WTRV. z 100 - Panel emergency When the red HELP Panel button is pressed. 4.6. Factory Reset z 101 - Personal emergency CTC-1052RV will clear all programmed parameters by the following sequence: When the Wrist Transmitter (WTR), Emergency Pendant or Fall Sensor is pressed. Step 1. Unplug the power cord from the DC Jack. z 102 –Inactivity Step 2. Remove the Battery Switch rubber cap.
z D#1014 - Device Low Battery every 2 secs with 2 beeps. z 380 - WTR Low Battery When other devices (except SD and WTR) are under Low Battery Status, Green LED flashes every 2 secs with 2 beeps whenever Low Battery signal is received from the device. When Wrist Transmitter (WTR) or Emergency Pendant is under Low Battery Status, Green LED flashes every 2 secs with 2 beeps. z D#1015 – Mobility/ Inactivity z 384 - Other devices Low Battery When CTC-1052RV Pro Mobility Check reporting.
When the red HELP alarm is canceled. z 155555517 - SD or CO emergency When the Smoke Detector (SD) or z 515155557 - Pendant 1 and Unit Button Carbon Monoxide (CO) is pressed. emergency When the Pendant 1 or Unit button is z 155555518 - SD or CO Low battery pressed. When the Smoke Detector (SD) or z 551555517 – Inactivity Carbon Monoxide (CO) is under Low Battery status, Green LED flashes every 2 secs with 2 beeps.
5.4.
DTMF DTMF CHARACTER COMMANDS ACK 44# Bi 45# Bi 46# Bi 47# Bi 49# Bi 60# Bi 61# Bi 62# Bi COMMAND OPERATION Mobility time 00= Disable, 01 ~ 36= 1 ~ 36 Hours Follow-On Choice, 0 = Wait command, 1 = Listen, 2 = Two way voice communication Follow-On mode & Two-Way Period, 01=1 min, 02=2mins, 03=3mins, 04=4mins, 05=5mins, 06=6mins, 07=7mins, 08=8mins, 09=9mins, 10=10mins.
5.5. CTC-1052RV SMS Remote Programming Command Table z If the SMS Keyword is set as PROG, and Access Code is set as 1111 (factory default).
CORRESPONDING DTMF CHARACTER COMMANDS 20# 21# 22# 23# 24# 31# ITEM Reporting method for all 4 Telephone numbers Reporting method for Telephone number 1 Reporting method for Telephone number 2 Reporting method for Telephone number 3 Reporting method for Telephone number 4 Ringer enable for incoming calls COMMAND FMATG FMAT1 FMAT2 FMAT3 FMAT4 ENRIN 32# Audible fault alert FAUTA 33# Help arrived signalling HELPA 34# Emergency button EMBUT 35# Silent mode SILMO 37# AC fault report A
CORRESPONDING DTMF CHARACTER COMMANDS ITEM 46# Follow-on & two-way period FOLTI 47# Off-set time OFFST 49# Supervision SUPPR 61# Check SIM card Pin code SIMPE 62# Input SIM card Pin code SIMPC COMMAND EXAMPLE & USAGE DEFAULT PROG 1111 FOLTI:02 05 = To set the duration for follow-on & two-way voice 5 minutes communication period 01-10=1-10 minutes PROG 1111 OFFST:1 To set the off-set time 1= 1 Hour 1=1 Hour, 2=2 Hours, 3=3 Hours 4=4 Hours, 5=8 Hours, 6=12 Hours PROG 1111 SUPPR:0 To set th
--- User name GPUSE --- Password GPASS --- Reset to factory default FTSET PROG 1111 GPUSE:123 To set/change the user name Input 1 to 15 alphanumeric characters PROG 1111 GPASS:65536 To set/change the password Input 1 to 5 digits No user name No password PROG 1111 FTSET:YyS 1. IP Address confirm (COMIP) & Port number confirm (COMPO) commands are used for GPRS server confiramtion purpose only. They do not change the IP address nor the port number settings. 2.
This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the installation, may cause harmful interference to radio communication.