User's Manual
10
when alarm can’t go through in digital
reporting method. Once alarm or
emergency data is successfully
transmitted, the CTC-1052RV will
automatically send out a SMS (CID)
Message.
Command 31
Ringer Enable for Incoming Calls
z CTC-1052RV can be programmed to emit
a ring tone as an audio alert, or silent for
incoming calls.
Function Selection Result
(0)
OFF
(Ring Tone Disable)
(1)
ON
(Ring Tone Enable)
z Factory Default is set as (0), OFF.
<
<
N
N
O
O
T
T
E
E
>
>
) If the function is set to ON, you can
answer the incoming call by pressing
the RED HELP BUTTON or Pendant
Button.
) The time-out period for the incoming
call is 30 minutes. During the
communication, CTC-1052RV will
emit two beeps via the telephone
handset to alert the call recipient the
remaining time of 20 & 10 secs.
) Press any DTMF keys (except
DTMF#9) can extend another 30 min.
) To terminate the incoming call: (1)
press the green reset button on CTC-
1052RV; or, (2) press DTMF #9 from
the call recipient’s end.
) During the AC Power failure period,
Ring Tone is automatically disabled.
Command 32
Audible Fault Alert
z CTC-1052RV can be programmed to emit
detected and existent Fault Alert Beeps at
every 30 secs.
Function Selection Result
(0)
OFF
(No Warning Beep)
(1)
ON
(With Warning Beep)
z Factory Default is set as (0), OFF.
z The fault situation includes Low Battery
Fault (for both CTC-1052RV and Devices)
and AC Failure.
Command 33
Help Arrived Signaling
This function is only available for the digital
Contact ID reporting method.
z It is used for the Monitoring Center
personnel to confirm if the help has arrived
for the user or not.
z If Help Arrived Signaling is set to ON, once
the Alarm Reporting is completed, the
RED HELP BUTTON will start to flash.
Press the GREEN RESET BUTTON when
the Help arrives, and CTC-1052RV will
report to monitoring center and the RED
BUTTON will stop flashing.
z If Help Arrived Signaling is set to OFF,
once the Alarm Reporting is completed,
CTC-1052RV will return to idle mode.
Function Selection Result
(0)
OFF
(Disable)
(1)
ON
(Enable)
z Factory Default is set as (0), OFF.
<
<
N
N
O
O
T
T
E
E
>
>
) If the GREEN RESET BUTTON is not
pressed within 15 minutes, CTC-
1052RV will send one more Help Call
report to summon help and inform the
Monitoring Center that no help has
arrived within the past 15 minutes.