12
after a successful alam reporting (triggered
by pressing the Help button on the Medical
Panel) to the Monitoring Center, CTC-
1052RV will automatically hang up the line
and start a 5-minute waiting period to auto
answer any incoming phone calls from the
Monitoring Center. The Monitoring Center
personnel should enter an authorized
access code (default: 1111), followed by (#)
to set up the two way communication
between CTC-1052RV and the Monitoring
Center.
If the alarm is triggered by a Talking
Pendant (WTRV/WTRVS), during the 5-
minute waiting period, the system will
wait for an authorized access code
(default:1111), followed by (#) to open the
two-way communciation between
WTRV/WTRVS and the Monitoring Center.
z When this function is programmed as (2),
after a successful alarm reporting
(triggered by pressing the Help button on
the Medical Panel) to the Monitoring
Center, CTC-1052RV will automatically
enter the Follow-On mode as specified by
Command (45). If the alarm is triggered by
a Talking Pendant (WTRV/WTRVS), the
system will automatically enter the “Wait
for Command” mode (skips to check
Command 45) and wait for the DTMF 2
signal pressed by the Monitoring Center to
set up the two-way communication
between WTRV/WTRVS and the
Monitoring Center.
Once Follow-On Mode is terminated, CTC-
1052RV will automatically start a 5-minute
waiting period to auto answer any incoming
phone calls from the Monitoring Center. The
Monitoring Center personnel should enter
an authorized access code (default: 1111),
followed by (#) to set up the two way
communication between CTC-1052RV and
the Monitoring Center. If the alarm is
triggered by a Talking Pendant
(WTRV/WTRVS), during the 5-minute
waiting period, the system will wait for an
authorized access code (default:1111),
followed by (#) to open the two-way
communciation between WTRV/WTRVS
and the Monitoring Center.
<
<
N
N
O
O
T
T
E
E
>
>
) During two-way communication, you
can use DTMF command to switch the
communicating method. Please refer to
section 4.2. Alarm Activation.
) The Access Code must be entered
within 15 secs. Otherwise, CTC-
1052RV will disconnect the call
automatically.
) To terminate the call, press DTMF (9)
or RESET BUTTON on CTC-1052RV.
) If the 5-minute waiting period is up,
CTC-1052RV will automatically exit
this waiting mode and return to idle
mode.
) During the AC Power failure period,
Call-Back function is automatically
disabled.
Command 40
Set Access Code
z The Access Code is used to enter
Programming Menu (locally or remotely),
and the Call-Back Function.
z It consists of 4 digits and has been set to
(1111) as factory default. Before you set
your own Access Code, (1111) must be
keyed in.
z To set a new Access code; enter the
desired (4-digit number)
in Function
Selection.
Command 42
Guard Time Delay
This command is deisgned for any
compitable sensor, except Fall Sensor.
z CTC-1052RV can be programmed to delay
alarm reporting from (00) (instant reporting)
to (99) seconds.
z During this time period, a continuous series
of beeps will be emitted to alert user.
z If a false alarm is triggered by any
compitable device, it can be cancelled
within the Guard Time Delay.
Function
Selection
Result