User's Manual
22
4.1.4. CTC-1052RV Low Battery
z CTC-1052RV continuously checks its own
Battery Condition 30 minutes after
powering up.
z When the battery low condition lasts for 4 -
6 mins
, CTC-1052RV will report to the
Monitoring Center and the GREEN LED
flashes slowly.
z Press the RESET
button to clear the
warning beeps, and the LED returns to
steady ON.
4.1.5. Devices Low Battery
z When CTC-1052RV receives a battery low
signal from a particular device, it will report
to the Monitoring Center and the GREEN
LED will flash rapidly until the fault
condition is cleared.
4.1.6. Automatic Check-in Report =
Periodic Test Call
z When CTC-1052RV is programmed to
send a periodical check-in report, CTC-
1052RV will report to the Monitoring
Center accordingly.
z The Periodic-Check-in Timer will be reset
whenever Programming Mode is entered.
4.1.7. Mobility Timer
z In order to check the user’s well being, a
Mobility Timer can be set by using
Command #44
.
z If Mobility Timer is set as Enable, a
counting down period starts from:
Immediately after powering up CTC-
1052RV.
Exit Programming Mode
z After the pre-set Timer expires, CTC-
1052RV will emit a beep at every 5
minutes to notify the user for 30 minutes.
z When the Mobility timer is not reset after
30 minutes, CTC-1052RV will send a
Mobility Timer Expired report to the
Monitoring Center.
z After CTC-1052RV sends a Mobility
Timer Expired Report, but the Mobility
timer still not be reset, when reaching next
pre-set time, the CTC-1052RV will emit a
beep at every 5 minutes to notify the user
for 30 minutes. Yet, if no reset action after
30 minutes, the panel will send another
Mobility Timer Expired report to the
Monitoring center and the step will
repeatly until Mobility timer is reset.
z Mobility Timer can be reset by pressing
RESET
button once on CTC-1052RV or
whenever a movement is detected by PIR
Detector.
z To disable the Mobility Timer function:
Set Command #44
to 00 (Disable), or,
Press and hold the RESET
button on
CTC-1052RV Pro for 16 seconds or
longer.
z
Disable the Mobility function in idle
mode:
Step 1: When the system is in Idle Mode,
press & hold the Reset Button for 16
seconds.
Step 2: During the 16-sec period, CTC-
1052RV will emit one short beep Æ a
double beep Æ continuous three short
beeps Æ a long beep.
Step 3: Release the Reset Button when you
hear the last long beep; a short beep
will sound to indicate the mobility
function is disabled.
<
<
N
N
O
O
T
T
E
E
>
>
) Please use Command #44 to enable the
Mobility timer again.
4.1.8. No Pendant Present
z This function is only available for the
digital Contact ID reporting method.
z If there is no pendent being learnt into
CTC-1052RV 30 mins after powering up, it
will send a No Pendant Learnt-in report
to the Monitoring Center and repeat every
hour thereafter, until a pendant is
successfully learnt in.
<
<
N
N
O
O
T
T
E
E
>
>
) The control panel will still send No
pendant Learnt-in report even when
1052RV is only Learning WTRV. But if
WTRB is learnt in, the control panel
won’t send No pendant Learnt-in
report.