User's Manual
18
5.1. Arming Setting
The Arming Setting includes parameters which affects system mode change function. Click “Edit”
to modify each setting.
Arm Fault Type: Select how the system should respond when it is being armed under
fault condition.
Confirm: The panel will first display a “Mode Change Fault” message and emit 2
beeps. Arming again within 10 seconds will force arm the system.
Direct Confirm: The system will be force armed directly without displaying fault
message and report an event.
Final Door: If set to On: When the system is Away Armed and under exit timer
countdown, if an opened Door Contact is closed, the system will automatically arm the
system even if the exit delay timer has not expired yet.
Entry Delay 1 for Arm Away: Set Entry Delay Timer 1 for Away Arm mode. When a
sensor set to Start Entry Delay 1 is triggered under Away Arm mode, the control panel
will begin Entry Delay Timer countdown according to duration set with this option
If the Control Panel is disarmed before the Entry Delay Timer expires, the panel returns
to Disarm mode and no alarm is activated. If the Control Panel is not disarmed before
the Entry Delay Timer expires, the alarm will be activated and the panel will send
report.
Entry Delay 1 for Arm Stay: Set Entry Delay Timer 1 for Arm Stay mode. When a
sensor set to Start Entry Delay 1 is triggered under Arm Stay mode, the control panel
will begin Entry Delay Timer countdown according to duration set with this option
If the Control Panel is disarmed before the Entry Delay Timer expires, the panel returns
to Disarm mode and no alarm is activated. If the Control Panel is not disarmed before
the Entry Delay Timer expires, the alarm will be activated and the panel will send
report.
Entry Delay 2 for Arm Stay: Set Entry Delay Timer 2 for Arm Stay mode. When a
sensor set to Start Entry Delay 2 is triggered under Arm Stay mode, the control panel
will begin Entry Delay Timer countdown according to duration set with this option
If the Control Panel is disarmed before the Entry Delay Timer expires, the panel returns