User's Manual

20
Entry Delay Sound for Arm Stay: this is for you to decide whether the Control Panel
sounds count-down beeps and volume of beep during the entry delay time in Arm Stay
mode.
Exit Delay Sound for Arm Stay: this is for you to decide whether the Control Panel
sounds count-down beeps and volume of beep during the exit delay timer in Arm Stay
mode.
Entry/ Exit Only Final Beeps: This is for you to determine when the Control Panel
should start warning beep during Entry or Exit countdown timer. For example, if the
setting is set to 5 seconds, the Control Panel will only stat warning beep during the last
5 seconds of Entry or Exit countdown timer. When set to Disable, the Control Panel will
sound warning beep during the entire Entry or Exit countdown timer.
Door Chime Setting: Select the volume for door chime notification sound.
5.3. Monitoring Station Settings
The Monitoring Station setting allows monitoring station reporting configuration.
Set/Edit Auto Phone Test: Set to turn ON or Off the auto phone test function. This
function must be set to ON for the other functions in this menu to be used.
Auto Check-in Interval: Set the waiting interval between each auto check-in report.
Note: This must be set to 6 hrs or smaller to meet the requirements of EN Grade 2.
Auto Check-in Offset Period: This is to set the time delay before the first Auto
Check-In report is made. After power is supplied or re-supplied to the Control Panel, a
test report will be sent to the Monitoring Station based on the Offset Period. This is
used to test whether the Monitoring Station is able to receive the report from the Panel
accurately.
Dialer Delay: Set the waiting time before dialing for report.