User's Manual
41
10. Appendix
Appendix A: Sensor Groups
Senso
r
Group
Physical
Type
Short Description Description Other
Allowed
Groups
0 Keypad/Pull
Station
Fixed Panic
24-hour audible fixed emergency buttons,
instant alarm, always armed
2, 4
1 Keyfob/Panic
Button
Portable Panic
24-hour audible portable emergency buttons,
instant alarm, always armed
3, 6
2 Keypad/Pull
Station
Silent Fixed Panic
24-hour silent fixed emergency buttons,
instant alarm, no siren, always armed
0, 4
3 Keyfob/Panic
Button
Silent Portable Panic
24-hour silent portable emergency buttons,
instant alarm, no siren, always armed
1, 6
4 Keypad Fixed Auxiliary
24-hour auxiliary sensor, instant alarm,
always armed
0, 2
6 Keyfob/Panic
Button
Portable Auxiliary
24-hour portable auxiliary alert button, instant
alarm, always armed
1, 3
8 Contact Cabinet/Safe
Special belongings, such as gun cabinets
and wall safes, instant alarm, always armed
8, 10, 11,
13, 14, 16,
19, 31, 36
10 Contact Door/Window
Entry and exit doors, standard delay alarm,
armed in Stay and Away modes
8, 11, 13,
14, 16, 19,
31, 36
11 Contact Extended
Delay/Door
Garage doors and entrances, extended delay
alarm, armed in Stay and Away modes
8, 10, 13,
14, 16, 19,
31, 36
13 Contact Door/Window or
Glassbreak
Exterior doors and windows, instant alarm,
armed in Stay and Away modes
8, 10, 11,
14, 16, 19,
31, 36
14 Contact Door/Window
Interior doors, instant alarm, armed in Stay
and Away modes
8, 10, 11,
13, 16, 19,
31, 36
15 Motion Motion
Motion Sensors, follower, armed in Stay
and Away modes
17, 18, 20,
25, 50
16 Contact Door/Window
Interior Doors, instant alarm, armed in Away
mode Only
8, 10, 11,
13, 14, 19,
31, 36