User's Manual
2
Supervision Programmable time frame for inactivity alert
Special Function Tamper Protection
GSM Standards Compiles with CE standards
EN Classification
EN Grade 2 Class II
Alarm Transmission Path Dual Path: DP1 (EN50136-1:2012)
Supported RCT
Alarm Report Server (ARS), Fibro, OH200, MasterMind, Manitou,
MicroKey and SIA DC 09
Mode of
Acknowledgement
Operation.
Pass-through (EN50136-2:2013, Clause 6.1.3)
Memory
DDR3L SDRAM: 512Mbyte
eMMC : 4GByte
Electrical
Power Source Built-in switching power supply, 100-240V, 50/60Hz input, 12V
1.5A output
Power Supply Type PS Type A, not suitable for use external to supervised premises.
Backup Battery 7.2V, NiMH 600mAh AAA rechargeable battery pack (built-in)
APS fault Low Voltage SD
signal threshold
7.3 V ± 3%
Battery Duration 14 hours
Battery Recharge Time to
80% of 600mAH
72 hours
Minimum Energy Level of
Backup Battery
86%
Current Drain
AC Powered
Average. 126mA/12V standby
839mA/12V full load
Battery Powered
Average. 42mA/7.2V standby
876mA/7.2V full load
Wireless
WCDMA Frequency
B1/B2/B5/B8
LTE Frequency
B1/B2/B3/B4/B5/B7/B8/B28/B40
RF Frequency 433.82MHz