User's Manual
37
Jamming Report: Jamming period is specified as background RSSI level detected
exceeding the threshold for a period.of time. The jamming period detected will be
accumulated.
3 options: Disable, 1 minute and 2 minutes are provided . If 1 minute is set, once the
total jamming period exceeds 30 seconds within 1 minute, a “Jamming” message will
be reported to the Central Monitoring Station . If 2 minutes is set, once the total
jamming period exceeds 60 seconds within 2 minutes, a Jamming message will be
reported to the Central Monitoring Station. If Diable is set, the control panel will not
send a jamming report to the Central Monitoring Station if a jamming fault is detected.
Auto Check-in: this is to select whether the Control Panel needs to send check-in
reporting to the Central Station automatically and to select the period of time between
check-in reports. Options available are Disable, 1 hour, 2 hours, 3 hours… up to 4
Weeks.
Auto Check-in Offset Period: This is to set the time delay before the first Auto
Check-In report is made. After power is supplied or re-supplied to the Control Panel, a
test report will be sent to the Central Monitoring Station (CMS) based on the Offset
Period. This is used to test whether the CMS is able to receive the report from the
Panel accurately.
After this test report is sent, the Control Panel will then send reports at regular interval
based on the setting of the Auto Check-in Report.
For example, if Offset Period is set to 2 Hours, and Auto Check-in Report is set to 12
hours, the Control Panel will transmit an event code 602 to the CMS after 2 hours, and
then report 602 event code periodically at a regular intervals of 12 hours.
IR Camera Resolution of Alarm Images: This is to select the resolution and number
of pictures taken by PIR Camera when the camera detects a movement in armed
mode.
Options available are 320x240x3 images (Default), 320x240x6 images and
640x320x3 images.
Outdoor IR Camera in Greysclae: This is to select whether pictures from Outdoor PIR
Camera should be taken in greyscale instead of color pictures.
Options available are: Disable (Color Picture) and Enable (Greyscale picture)
Bypass Ethernet: Select to enable or disable Bypass Ethernet function. When YES is
selected, the Control Panel will bypass connection fault when Ethernet cable
unplugged status is detected.
Area Setting
Area: Select operation area to apply setting.
Final Door: If set to On: When the system is Away Armed and under exit timer
countdown, if a opened Door Contact set to Entry attribute is closed, the system will
automatically arm the system even if the exit delay timer has not expired yet.
Arm Fault Type: Select how the system should respond when it is being armed under
fault condition.
Confirm: The panel will first display a “Mode Change Fault” message and emit 2
beeps. Arming again within 10 seconds will force arm the system.
Direct Confirm: The system will be force armed directly without displaying fault
message and report an event.
Tamper Alarm: Select whether the siren should sound alarm when the tamper is
triggered.
Full Arm: when tamper is triggered under Full arm mode, Control Panel raises a