User's Manual

Table Of Contents
1 Cover Fixing Screw
2 LED 1 - Area 1 (Green/Red)
Full Arm mode - Red lighting up
Home/1/2/3 mode - Red flashing
Learning mode - Green lighting up
Walk Test mode - Green flashing
3 LED 2 - Area 2 (Green/Red)
Full Arm mode - Red lighting up
Home/1/2/3 mode - Red flashing
Learning mode - Green lighting up
Walk Test mode - Green flashing
4 LED 3 - Status (Orange/Red)
System Fault - Orange lighting up
Alarm Trigger Red flashing
Aarm in Memory Red lighting up
5 Removable Protective Cover x 4 (at top and bottom of the back cover)
Removable cover to reveal or hide cable wiring hole.
6 Mounting Holes x 4
7 Wiring Clip x 4
8 LED Board Connector
9 EGND Terminal
Please refer to 3.3 Hardware Installation for detail.
10 J24 Jumper Switch
Please refer to 3.3 Hardware Installation for detail.
11 RS485 Terminal
Connect to a hardwired keypad (KPT-35-Combo), or wired expansion module (WEZC-8).
Up to 32 hardwired KPT-35-Combo can be connected in parallel.
12 Bell Terminal
Connect to a wired bell box for bell wiring.
13 PGM Port
To be used as a voltage output port or a dry contact relay output depending on J24 jumper
settings.
14 SLA Backup Connection Battery Terminal (not hot swappable)
Connect to SLA battery pack, up to two battery packs can be connected.
15 Alternative Hole for Wiring Management x 2
16 Built-in Power Unit (Input: 16 ~ 18VAC 40VA or 100-240VAC)
AC module built-in power unit or Open Frame built-in power unit is installed. Use the built-in
power unit to connect to the mains power.
Ensure to turn off all power supplies including Built-in Power Unit and SLA
Battery before connecting or removing cables or wires.
17 Wire Saddle
7