Vesta Smart Home Alarm System MLx-xxx Series (x=0~9, A~Z or blank)
Table of Contents 1. Application Overview__________________________________________________ 1 1.1. Parts Identification _______________________________________________________ 1 1.2. The Power Supply ________________________________________________________ 5 1.3. How to Install the Control Panel ____________________________________________ 5 1.4. Multi-User Passwords ____________________________________________________ 5 1.5. System Basic Operation___________________________________________________ 6 1.6.
.7. Device +/- ______________________________________________________________ 22 4. Operation __________________________________________________________ 22 4.1. LCD Display____________________________________________________________ 22 4.2. Entering User Menu _____________________________________________________ 23 4.3. Away Arm Mode ________________________________________________________ 23 4.4. Home Arm 1/2/3 Mode ___________________________________________________ 23 4.5.
1. Application Overview 1.1. Parts Identification Front View Back View (With Back Cover) 1. Backlit LCD Display 6. Away Arm Key: Use this key to Away Arm the system. 2. Power LED (Green) 7. Home Arm Key: Use this key to Home ON: AC Power on. Arm the system. OFF: AC Power failure. 8. Disarm Key: Use this key to Disarm the 3. Microphone system. 9. Key: Press and hold for 3 seconds to 4. Fault LED (Amber) enter Installer Menu ON: Fault exists in system 10.
device for control through the External Output Terminal is required. 1.2. The Power Supply The Control Panel is powered by a DC12V 2A AC adaptor which is supplied in the package. Step 5. Connect the DC12V 2A adaptor to the panel. Rechargeable Battery Step 6. Slide Battery Switch to ON position. In addition to the adapter, there is a Step 7. Break through the side of back cover for wiring. Step 8. Hook the Control Panel onto the back cover on the wall. Step 9.
automatically exit the menu and return to disarm mode. Installer Code The Installer Code is for installer to If the Control Panel lost power supply. program system configurations under installer menu, such as Tel. Number, Account Number. When the power is restored, it will resume its previoius mode. When programming settings, refer to the When the display panel asks for I-Code, following tables to enter symbols and alphabets, press the key repeatedly until the desired symbol/alphabet appears.
number will also be displayed on the top right corner of the LCD screen. The RSSI scale is 0-9, the greater the number, the better the signal strength. 2. System Configuration In order to configure the Control Panel setting, you need to enter the Installer Menu. To enter the Installer Menu: 2.2. Install Code Step 1. Under Disarm mode: For touch keypad panel, press any key to activate the keypad. Keypad backlight will light up. This function is for you to edit the Installer code Step 1.
Step 7. Select a group for the report destination. built-in siren and any external siren/bellbox learnt into the Control Panel function The reporting priority is based on to group number sequence. From Group 1 Group Group 2 Group 3 ….etc Step 1. Select Test Siren and press OK to confirm.
Pr e s s OK t o P - Wo r d s t o p P ROG Step 2. The screen will display current P-word. Enter the new keyword if you want to edit keyword, press OK to confirm. 2.8. Panel Setting The Panel Setting menu allows you to program Control Panel configurations. This is for you to set the waiting time for the Control Panel to make report after detecting AC failure. Factory default is set to 5 minutes. Step 1. Select Panel Setting and press OK to confirm.
select a new option and press OK to confirm. Handsfree You can Enable or Disable to handsfree telephone calling function on this panel. Offset Period This is to set the time delay before the first Auto check-in report is made whenever the Control Panel was powered off, then on again, or when Auto check-in interval time is changed.. Factory Default is set to 1 hour. Step 1. Select Hand free and press OK to confirm. Step 1. Select Offset period and press OK to confirm. 1 h r 2 h r . . . . . .
press OK to confirm. External Tamper This is for you to enable/disable the external tamper function. Factory default is set to Disable. This is for you to set whether you want to ignore fault events regarding Ethernet or RFfunction. Bypassed fault events will not displayed or cause the fault LED will to light up and emit beeps. Step 1. Select External Tamper and press OK to confirm. Di s a b l e En a b l e Step 1. Select External Tamper and press OK to confirm. Di s a b l e I P Step 2.
T T S A a o y u i k d c p y n k Confirm: When set to Confirm, If you attempt to arm when a fault exists within the system, the arming action will be prohibited, and a message will be displayed “Fault exists! Please Confirm!” You need to arm the system again to confirm your action and arm the system. (Factory Default) e i o e y l a n d Step 3. The screen will display current time zone setting, To change the setting, select a new option and press OK to confirm.
Di s a b l e 4 h r 6 h r . . . . . . 1 d a y . . . . . . 7 0 s e c Step 3. The screen will display current setting. To change the setting, select a new option and press OK to confirm. Step 2. Select your desired Supervision time, press OK to confirm. Exit Time When you arm the system, the Control Panel will begin an Exit Delay countdown timer according to your Exit Time setting, and enter selected arm mode after the timer expires.
Control Panel will sound beeping sounds every 30 seconds when fault exists within system. 2.10. Device +/Devices +/menu allows you to add/change/delete all available devices. A total of 40 devices can be included in the Control Panel. Step 1. Select Device +/- and press OK to confirm.
Home Omit When the system is in Home Arm 1/2/3 mode, if a “Home Omit” device is triggered, the Control Panel will not raise alarm. It will still send a report for this event When the system is in Full Arm mode, if a “Home Omit” device is triggered, the Control Panel will respond in the same way as if a “Burglar” device is triggered. When the system is in Home Arm 1/2 mode, if a “Home 1/2 Omit” device is triggered, the Control Panel will not respond.
Panel will not respond after the delay period expires, a Burglar Alarm will be reported and the external sirens included in the Control Panel will also be activated. Disarming the Control Panel within the 30 second period will return the system to Disarm mode and silence the built-in siren. No alarm event will be reported. When the system is in Disarm mode, the Control Panel will make a “ding-dong” Door Chime sound on “Entry” (if Door Chime function is not disabled).
be reported. L a L i L i L o Ma Pa Pa Re Ro Si St St T o Ya Step 5. Select if you want to permanently bypass the device. Permanently Bypass will deactivated selected device until you unselect the function. The Control Panel will ignore all signal sent from Permanently Bypassed device, include Low Battery and Tamper signal. Press OK to confirm. Factory Default is Normal. N o r ma l P e r ma n . By p a s s Step 6. Select to on or off latch report.
For SR-15 or BX-15, please learn in the siren according to the instruction in Add Device. The Control Panel’s current local area network IP will be displayed Siren Tamper On/Off Siren Tamp.On: When selected, the Siren’s tamper protection will be enabled. DHCP On: If DHCP is set to On, the Network will obtain the IP address automatically with a valid Network DHCP Server. You do not need to do any settings. You can only set DHCP to On if your Network environment supports DHCP.
destination, please refer to Media Upload section. 1 2 3 4 5 P Step 1. To edit the email information, select SMTP and press OK to confirm. Step 2. Proceed to enter the IP address, press OK to confirm. S MT P The format of SMTP setting smtp://user:password@mail server 1~5 There are 5 upload destinations available for you to program. is: Step 1. Select one of the upload destination from 1~5, press ok to confirm. User: email account user name. For example, if your email account is john@yahoo.
Lower Temp. Zone The rule will be activated when the temperature of the selected temperature sensor drops below set temperature. 2.14. Home Automation The Home Automation function allows you to set rules to customize your output terminal and control the device connected to the terminal with preset condition. Timer The rule will be activated according to set time.. Initial. Step 1. Select Home Auto. and press OK to confirm. The rule will be activated when the Control Panel is powered up. Step 2.
asked whether you want to delete the PIN code (except for PIN code 1 which cannot be deleted), press OK to confirm if you want to delete the PIN code For an empty PIN code, you will be prompted to enter a new code. Step 1. Under Disarm mode: For touch keypad panel, press any key to activate the keypad. Keypad backlight will light up Step 2. Press and hold the # key on the numeric keypad for 3 seconds. En t e r You will be prompted a PIN code.
Step 1. Select Temp Code and press OK to confirm. You will be prompt to enter a new Temporary Code. En t e r n e w c o d e . . . . 4. Operation 4.1. LCD Display Step 2. Enter the new code and press OK, you will be asked to repeat the code again. Re p e a t n e w c Od e . . . . The Control Panel’s LCD will display the system information according to different status and panel modes. Step 3. Repeat the new code and press OK to confirm. Temporary Code setting is now complete.
User PIN code and press the Away Arm key on the Control Panel. When fault event exists in system, press Down key to view fault events. When under Disarm mode, enter a User PIN code and press the Away Arm key on the Remote Keypad. (Please refer to Remote Keypad manual for detail) Press the Away Arm key on the Remote Controller When under Disarm mode, press the Away Arm key on the Control Panel for quick arm.
When under Disarm mode, enter a User PIN code and press the Home Arm key on the Control Panel. (Home Arm 1 only) When under Disarm mode, enter a User PIN code and press the Home Arm key on the Remote Keypad. (Home Arm 1 only, please refer to Remote Keypad manual for detail) Press the Home Arm key on the Remote Controller(Home Arm 1 only). When under Disarm mode, press the Home Arm key on the Control Panel for quick arm (Home Arm 1 only, Quick Key arming must be enabled in Panel Setting).. 4.
You can activate programmed Scene number under the User Menu. Before applying a scene, the scene must be programmed first through the Control Panel webpage. Please refer to the IP Installation Guide for detail. Step 1: To Stop the alarm, disarm the Control Panel, please refer to 4.5. Disarm for detail. Step 2: The alarm will be stopped, the device that triggered the alarm will be displayed on screen.
The Control Panel will dial a number during voice reporting. When the call recipient picks up the phone, the Control Panel will delay 5 seconds before starting to play the message. report and CMS call back within the Callback Timer. When the Control Panel makes a Voice report and the call recipient presses DTMF “1” key. When the Control Panel receives an incoming call during the Calback timer after making a report. When an user dials a number using the Handsfree function of the Control Panel.
The Control Panel is tamper protected from unauthorized cover opening or removal from mounted surface after installation by the Tamper Switch on the back of the Control Panel. An additional tamper switch can be connected to the External Tamper Switch Terminal on the Control Panel. The terminal will form a Normal Close loop with the tamper switch and activate when the loop is opened. When the tamper is triggered: END Step 3.
emit 2 beeps to indicate. Step 2. Apply power to the control panel. Step 3. Press key within 10 seconds after power on the panel. Step 3. Enter the following DTMF commands: 1: Disarm the system. The panel will play voice message to confirm. Step 4. The Control Panel firmware version will be displayed. 2: Home arm the system. The panel will play voice message to confirm. Step 5. To factory reset the panel, press the following keys: , then OK key to confirm 3: Away arm the system.
4.17.
Fire Instant Fire Alarm Instant Fire Instant Fire Instant Fire Instant Fire Instant Fire Instant Fire Instant Fire Alarm Alarm Alarm Alarm Alarm Alarm Alarm Instant Medical Alarm Instant Medical Alarm Instant Medical Alarm Instant Medical Alarm Instant Medical Alarm Instant Medical Alarm Instant Medical Alarm Instant Medical Alarm Water Instant Water Alarm Instant Water Alarm Instant Water Alarm Instant Water Alarm Instant Water Alarm Instant Water Alarm Instant Water Alarm Instant Water
137 – Panel Tamper 5. Appendix When the Control Panel tamper switch is triggered. 5.1. Event Code 100 – Medical 139 – Verification / Alarm Confirmation 101 – Personal emergency 147 – Sensor Supervisor Failure When the Control Panel fails to receive the signal transmitted from any one of the devices individually for a preset period. When the Wrist Transmitter / Emergency Pendant (WTR) is pressed.
389 – Self Test Failure 400 – Arm/Disarm (by Remote Controller) When the system is armed or disarmed by using the Remote Controller. 401 – Arm/Disarm by Panel When the system is armed or disarmed by entering the PIN code. 408 – Set/Unset Disarm 407 – Disarm/Away Arm/Home Arm by Remote Keypad 465 – Alarm Reset 570 – Zone Bypass When fault exists in system, and the system is armed by ignoring the fault event.