User's Manual

VCM manual 2006.08.07
1
VCM – Valve Control Machine
IDENTIFYING THE PARTS
TOP VIEW:
1) Red LED
This Red LED is used for indicating different operation
status of VCM.
- When the LED is OFF, the system is in Normal
operation mode.
- When the LED is ON, the system is in Learn Mode for
additing/deleting devices or motor.
- When the LED is Flashing in duty cycle, the device is
out-of-order.
- When the LED is Flashing quickly, the VCM is
transmitting signals.
REAR VIEW
:
2) DC Jack
For connecting the DC 6V 2A power adaptor.
3) Rock Switch (3 way)
This Rock Switch is used to manually open/close the
valve control. When the switch is slid either upward
or downward and released, it will automatically return
to central position.
- Slide UPWARDS: to Open the Valve control
- In Central position: Valve control is in Stand-by mode
- Slide DOWNWARDS: to Close the Valve control
<NOTE>
" The up and down direction is marked by arrow indication on the side of VCM plastic cover.
4) Red Tack Switch
This Red Tack Switch is used for Device or Motor Learning, Removing Fault Device and Resetting
the System to Factory Default.
a) With 1 press only
:
it will transmit a test signal to Dialer; Red LED flashes quickly during the transmission.
¾ for one-way radio transmission: beep once
¾ for two-way radio transmission: beep once only if the panel receives confirmation from VCM
b) Press and hold for 5 secs:
for entering Device learning process
c) Press and hold for 10 secs:
for entering Motor learning process
d) Press and hold for 15 secs:
1
3
4
5

Summary of content (11 pages)