User's Manual
VCM manual 2006.08.07
5
The VCM installation is now ready for use.
LEARN-IN PROCESS
MOTOR LEARNING PROCESS
During the Motor Learning Process, the LED will stay ON and beep in duty cycle until the learning process is
finished.
Step 1. Press and hold the Red Tack Switch on VCM for 10secs. 2 beeps will be performed with an interval
of 10 secs.
Step 2. Release the Red Tack Switch. Motor will close and open valve twice for self-testing.
Step 3. If the learning process is successful, it will perform 2 beeps.
If the learning process is unsuccessful, it will beep 4 times.
<NOTE:>
" If 4 beeps is performed by VCM, please repeat the learning process from Step 1.
Step 4. VCM will automatically exit Motor Learning mode and return to Stand by mode.
<NOTE:>
" The Valve control will shut off automatically after the learning process is completed.
WHEN VCM IS A STAND ALONE SYSTEM
RS/WS-LD Learning Process
Step 1. Program the VCM by pressing and holding the Red Tack Switch for 5 secs, a short beep will be
sounded. Then release the switch, VCM will perform a long beep with LED ON to indicate it has
entered Learn Mode.
Step 2. Press the test button on RS/WS-LD. VCM will perform 2 beeps with LED flash if the signal is
received successfully.
<NOTE:>
" For more detail, please refer to the user manual of RS/WS-LD.
" Each VCM can learn up to 10 devices.
WHEN VCM IS A DEVICE
(A) Learning to dialer CTC-1040:
Step 1. Put the CTC-1040 to Program mode by pressing # + Pin code + ACK. A long beep is sounded by
the dialer, and its Power LED Red goes ON.
Step 2. Put the CTC-1040 to Learn mode by pressing Test + 9. The dialer enters learn mode by
indicating Power LED Red as ON, Fault LED as Flash.
Step 3. Press Red Tack Switch on VCM. The CTC-1040 sounds 2 beeps, Fault LED goes OFF and Dialer
LED goes ON for 10 secs, to indicate that learn-in has been successful.
Step 4. Refer to the operation manual of CTC-1040 under the section of “Learning Sensors” for more
details.
(B ) Learning to dialer CTC-1042: