User's Manual
WS-LD.DOC 2006.01.26
2
I
I
I
I
.
.
F
F
o
o
r
r
V
V
C
C
M
M
:
:
Remove the battery lid by pushing and sliding it with the direction of arrow on the bottom of
WS-LD
Insert the battery with negative of the battery on the spring side.
Clips the battery lid to the base.
Program the VCM by pressing and holding the red button on the bottom for 5 secs, a short
beep will be sound. Then release the button, VCM will perform a long beep will with LED On..
Press the red button on WS-LD.
VCM will perform two beeps with LED flash if the signal received successfully and completes
the learning-in procedures.
<
<
N
N
O
O
T
T
E
E
>
>
VCM will perform one short beep indicating that the WS-LD is already in the system.
M
M
O
O
U
U
N
N
T
T
I
I
N
N
G
G
W
W
S
S
-
-
L
L
D
D
:
:
I. Clean the surface with a suitable degreaser.
II. Remove the protective covering from one side of the double-sided adhesive pad
and firmly apply to the back of the device.
III. Next remove the other cover and firmly press the item onto the desired location.
<
<
N
N
O
O
T
T
E
E
>
>
Do not use the adhesive pad method of installation on a surface with peeling or cracked
paint, or on a rough surface.
N
N
O
O
R
R
M
M
A
A
L
L
O
O
P
P
E
E
R
R
A
A
T
T
I
I
O
O
N
N
:
:
Mount the WS-LD on the wall whereas drop the black wire onto the floor level or any height that you
want to detect the increasing water level.
When the probes first come in contact with water, WS-LD gives out continuous warning
beeps at a 50% duty cycle for every two seconds, and sends an alarm signal to the
control panel every two minutes to notify the user.
With water condition persists, WS-LD will keep performing the warning beeps and
sending the alarm signal to the control panel
<
<
N
N
O
O
T
T
E
E
>
>
After probes are no longer in contact with water, the warning beeps will be eliminated and
WS-LD sends a restore signal to the Control Panel indicating the water condition has been
cleared. WS-LD then enters Normal Operation Mode.
During the alarming period, whenever the water ebbs, WS-LD enters Normal Operation
Mode.
S
S
u
u
p
p
e
e
r
r
v
v
i
i
s
s
o
o
r
r
y
y
S
S
i
i
g
g
n
n
a
a
l
l
After installation, the WS-LD will automatically transmit Supervisory Signals periodically to the Control
Panel at intervals of 24 hrs randomly.