The Device tab allows user to learn in or remove devices from CTC-1052-QT-DT35A. The
system can learn a total of 20 sensors. All learnt-in devices will be assigned to zone 1-20
sequentially.
93# Learn-In Silent Device:
- This is used for learning in silent devices. When
CTC-1052-QT-DT35A receives the alarm signal
from a Silent Device, it will not sound any warning beeps during Reporting and Guard time
period.
94# Learn-In Device:
- This is used for learning in non-silent devices.
The available devices that can be learnt-in via Command #93 and #94 are:
PIR Sensor ----- PIR
  Smoke Detector ---- SD
  Carbon Monoxide Detector---- CO
  Fixed Panic Button ---- PB
  Wrist Transmitter ---- WTR
  Pendant Transmitter ---- WTR
  Water Sensor ---- WS
  Fall Sensor ---- FS
Carbon Dioxide Detector ---- CO2
Temperature Sensor ---- TS
To learn a silent device or a non-silent device:
Step 1: Depending on the device type, click the Start button besides 93# (Silent Device) or the Start
Button besides 94# (Device) to enter learning mode, a “Panel in learning mode. Please press
Device Button!” message will pop up.