User's Manual

39
absence of battery in the following cases:
Battery not connected
Battery failure.
When the battery disconnection lasts for
10-15 minutes, CTC-1052-QT-DT35A will
report to the Monitoring Center and the
GREEN LED will flash slowly.
After the battery is restored for 10-15min,
CTC-1052-QT-DT35A will send Battery
Restore report to Monitoring Center and
the GREEN LED returns to steady ON.
5.1.5. Devices Low Battery
When CTC-1052-QT-DT35A receives a
battery low signal from a particular device,
it will report to the Monitoring Center and
the GREEN LED will flash rapidly until the
fault condition is cleared.
Press the Reset Button on CTC-1052-QT-
DT35A, the LED will turn on.
If any device Low Battery signal is received
again, the LED will light up accordingly.
Press the Reset Button again, the LED will
turn on.
After the faulty battery is replaced, CTC-
1052-QT-DT35A will immediately send
Battery Restore report to the Monitoring
Center for that particular device.
5.1.6. Automatic Check-in Report =
Periodic Test Call
When CTC-1052-QT-DT35A is
programmed to send a periodical check-in
report, CTC-1052-QT-DT35A will report to
the Monitoring Center accordingly.
The Periodic-Check-in Timer will be reset
whenever Programming Mode is entered.
5.1.7. Mobility Timer
In order to check the user’s well being, a
Mobility Timer can be set by using
Command #44.
If Mobility Timer is set as Enabled, a
counting down period starts from:
Immediately after powering up CTC-
1052-QT-DT35A.
Exiting Programming Mode
After the pre-set Timer expires, CTC-1052-
QT-DT35A will emit a voice prompt
reminder “Inactivity timer expiring, please
reset.” every 5 minutes to notify the user for
30 minutes.
When the Mobility timer is not reset after 30
minutes, CTC-1052-QT-DT35A will send a
Mobility Timer Expired report to the
Monitoring Center.
After CTC-1052-QT-DT35A sends a
Mobility Timer Expired Report, but the
Mobility timer was still not reset, when
reaching next pre-set time, the CTC-1052-
QT-DT35A will emit a beep every 5
minutes to notify the user for 30 minutes.
Yet, if no reset action after 30 minutes, the
panel will send another Mobility Timer
Expired report to the Monitoring center and
the step will be repeated until Mobility timer
is reset.
Mobility Timer can be reset by pressing
RESET button once on CTC-1052-QT-
DT35A or whenever a movement is
detected by PIR Detector. CTC-1052 will
also play a voice prompt “Inactivity timer
reset.” to inform the user.
To disable the Mobility Timer function:
Set Command #44 to 00 (Disable)
<NOTE>
If no movement is detected during preset
mobility time, CTC-1052-QT-DT35A will
send a CID event code 641 with a fixed
zone number 071 regardless of the zones
the triggered motion detectors occupy.
5.1.8. Country Code
The Phone Number Format for each SIM card
may vary between different Telecom companies.
Thus, you can either check with your Telecom
provider or follow the steps described below to
check the correct format.
Step 1: Remove the SIM card from SIM card
holder on the Panel, and insert it into a
workable mobile phone.
Step 2: Power on the mobile phone and send
a test SMS message to another mobile
telephone number.
Step 3: Once the test message is received,
you can then check the phone number
format shown in the received message.