User's Manual

4
2. Learn-in the Devices
There are three methods to learn in devices:
command learning, local learning, and using
Device ID. The system can learn a total of 20
sensors. All learnt-in devices will be assigned
to zone 1-20 sequentially.
2.1. Command Learning
Command Learning:
1. The user can use Commands 93-94 to
learn devices into the system.
2. Command 93 is designed to learn in
devices for silent reporting, including
WTR, Fall Sensor, or Panic Button.
3. Command 93 & 94 is designed to learn
in the following devices and sensors.
PIR Sensor ----- PIR
Smoke Detector ---- SD
Carbon Monoxide Detector---- CO
Fixed Panic Button ---- PB
Wrist Transmitter ---- WTR
Pendant Transmitter ---- WTR
Water Sensor ---- WS
Fall Sensor ---- FS
Carbon Dioxide Detector ---- CO2
Temperature Sensor ---- TS
Please refer to 4.2 Programming Your 1052-
QT-DT35A: Commands 93-94 for details.
The PC Programming Tool (1052-QT-DT35a-
Tool) also supports Command Learning.
Please refer to 4.4 PC Programming Mode
4.4.1.5 Device for detailed instructions.
2.2. Local Learning
Local Learning:
The user can also use the local learning
method to learn in all devices.
1. When the device is learnt in for the first
time, voice prompt will prompt the
device/sensor name and “learned.”
2. Within 3 minutes after exiting learning
mode, the control panel will emit 1 long
beep everytime it receives a test code (from
any device).
To enter Local Learning Mode:
1. Press and hold the Learn Button of the
CTC-1052-QT-DT35A. When pressed, the
CTC-1052-QT-DT35A will emit one beep
sound initially, and then emit a double beep
on the 6
th
second followed by a voice
prompt “Release the button, Ready to learn
sensor.” Release the Learn Button right
after the double beep and the voice prompt.
2. CTC-1052-QT-DT35A is now in learning
mode and the Purple backlight will turn on.
3. Press the (Learn) button on the device or
sensor. Voice Prompt: “(Name of Sensor)
learned.”
4. If no action within 10 seconds after “Ready
to learn sensor” prompt, CTC-1052-QT-
DT35A will prompt “Press sensor button.”
This prompt will repeat two times if no
action.
5. If no action after second “Press sensor
button” prompt, CTC-1052 will prompt
“Press the button to exit.” This prompt will
be repeated three times if no action
continutes.
6. If no action (no device button is pressed)
after 5 minutes, the CTC-1052-QT-DT35A
will automatically exit Local Learning Mode
and return to idle mode. Voice Prompt: “We
are now in Normal Operation Mode.”
2.3. Learn-In Device using
Device ID
If sensor device ID is given (please consult
the supplier), the users can learn the device
into the Control Panel using device ID.
User can use SMS commands or the
programming tool SMS iWizard (sold
separately) to learn devices using device ID.
Please refer to the table CTC-1052-QT-
DT35A SMS Remote Programming
Command Table or the SMS iWizard
operation manual on how to learn in devices
into different zones using device ID.