Multi-functional Programmable Controller CE-PTZ-KEY User Manual VER34<01> System Keyboard DVR MUX MENU SET/ POWER SHOT/ DVR ALM/ GRP/ AUX/ RUN/ upply * pply to ON/ PREV/ 8 NEXT/ 9 0 SYS IRIS MON 6 Tx OPEN/ BACK AUTOPAN/ 3 5 4 7 to Wal l HOLD/ 2 1 RJ45 C able OFF/ Rx MUX CLOSE/ DEL FAR/ PIC.L FOCUS NEAR/ PIC.F WIDE/ PgUp ZOOM TELE/ PgDn CAM CLR ENTER Outlet Wall O u tlet CLINTON Electronics 6701 Clinton Road Loves Park, IL 61111 1.800.447.3306 Sales 1.800.
Introduction Congratulations on the purchase of your new CE-PTZ-KEY. This device is a multifunctional, programmable keyboard controller for Pan-Tilt-Zoom devices, DVRs, and Matrix devices, and can be programmed with individual protocol settings for each connected device. It is equipped with a 3-Axis joystick for performing Pan, Tilt, and Zoom with a single hand.
S / NEXT / NEAR.F PIC E/ TELDn Pg / ALM N MO GRP/ CAM 1 6 SE 2 HOLD 7 R ENTE Power 5 PAN/ AUTO + RS485 + DC12V + DC12V T RS232 RJ45 3 / MUX Tx FAR/.L PIC Keyboard Adaptor 5) (No: 1437 RS-232/ Power R T R RS2322 GGND GND RS23 DC12V RS485 / WIDE PgUp SYS ZOOM / NEAR.
Precautions For all service or installation needs, please refer to qualified service personnel or system installers Do not attempt to disassemble the device To prevent electric shock, do not remove screws or cover. There are no user-serviceable parts inside. Contact qualified service personnel for maintenance Handle the device with care Do not strike or shake, as this may damage the device. It should be protected against extreme pressure, vibration, and humidity during transportation and storage.
WARNING TO REDUCE THE RISK OF ELECTRIC SHOCK OR FIRE, SO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. DO NOT INSERT ANY METALLIC OBJECTS THROUGH THE VENTILATION GRILLS OR OTHER OPENINGS ON THE EQUIPMENT. This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
Installation Safety Instructions before starting - Do not install and operate this appliance in a flammable and explosive environment. - Make sure that the installation is done according to the local electricity safety regulations of your country. - Before installation and maintenance, make sure that the appliance is disconnected from the power source. - Handle the device during installation carefully. Falls or extreme vibration may cause irreparable damages or void the warranty.
Installation Connection Schematic The keyboard can be connected to various PTZ cameras, DVRs, and Matrix devices through the keyboard adaptor. All accessories are tested for maximum compatibility and best performance. For the first start, please ensure your keyboard parameters match those shown on the initial screen (ie. protocol, baud-rate, ID). Doing so will allow you to enter the OSD for further settings.
Installation Star-ConnectionThe star-form connection is most commonly used. It enables the connection of different dome cameras with longer cable runs. It is recommended to use an RS485 distributor to ensure the telemetric data transmission. RS 485+ RS 485- Tx > 4<01 oard VER3 Keyb em Syst Rx ER SYS POW The advantage of the star-connection is that every channel can work independently and can take a cable length up to 3,280 feet (1000 meters) (depending on cable quality).
Tx SYS UX E/ WIDUp Pg FAR/.L PIC M ZOO US FOC RIS R/ NEAC.F PI SE/ CLOEL D / TELE n PgD Installation Key Description CLR LCD Display with backlight ER ENT 1. Camera Operation Keys Tx 01> rd 34< boa VER m Key te Sys 8-1/4” MUX DVR / / GRP PRE / 2. Operation Keys / TELE n PgD R/ NEAC.F PI SE/ CLOEL D N MO 3 CAM 2 1 3. T/ HOLD / RUN / AUX NEX V/ ZOO US FOC IRIS OFF ALM 3-Axis Joystick M / PAN AUTO ON/ / / E/ WIDUp Pg FAR/.L PIC N/ OPECK BA 5.
Operation VERxx<01> System Keyboard SET MUX PROTOCOL >ROBOT VERxx<01> VERxx<01> SETThe MUX PROTOCOL SET MUX PROTOCOL Initial SetupAfter power up, the keyboard will start the initialization and self-test. LCD MON--CAM- ALMpress menu key to exit startup screen System Keyboard VERxx<01> >ROBOT System Keyboard SET MUX PROTOCOL 001 0001 >ROBOT 0001 MON display will show initial startup screen. Press MENU to start using the keyboard.
RJ45 PRE D/ / NEX V/ T/ SE/ CLO DEL HOL RUN / R/ NEA PIC.F / TELE n PgD RS485 + DC12V + DC12V + RS232 T RS232 R RS232 G DC12V RS485 - OFF / ALM DC12V ZOO RS-485/ M US FOC IRIS GRP / E/ WID p PgU FAR/ PIC.
PTZ C Channel VERxx<01> MUX PROTOCOL IN:01 CAM:0001 Monitor PASSWORD : MON--- CAMInputSET 01 : >NVIDO screen after its connected This may beCamera necessary Alarm the first DVR>ROBOT ID System Keyboard Monitor ID for output ADMIN AUTHORITY SET DVR : 001 0001 type in the camera number time you connect your keyboard, ********** Set DVR ID: 001 0001 0001 SET DVR : >SET_CHANNEL> wishkey to control: example: even if it shows “CAM-0001” on pressyou menu to exit startup screen ALL >9600bps Camera ID DVR CH:ID 01<
Working with PTZ Start PTZ mode By default, the keyboard usually starts in PTZ mode (display shown below). You can also access the PTZ menu by pressing the MENU button. SET MUX PROTOCOL >ROBOT MON--- CAM- ALM001 0001 0001 SET MTX BAUD RAT Select / Change >9600bps CAM+# SET+# SHOT+# current camera-001 0001 0001 001 0001 0001 001 0001 0001 By default, the keyboard usually starts in PTZ mode (display shown below).
ET MUX PROTOCOL Working ROBOT with DVR MON--- CAM- ALM001 0001 0001 Virtual PTZ control in DVR mode CAM+# SET+# SHOT+# this mode, you can001 control simultaneously: by selecting the input on the DVR, 0001the 0001DVR and 001 PTZ 0001 0001 001 0001 0001 the PTZ ID assigned to this channel will be automatically selected and ready tor PTZ control (DVR and Seq Pos Spd Ti PTZ ID assignment need to be set up prior to operation.
Multiplexer SHOT+# # 0001 0001 001 0001 0001 Control Press the MUX button to enter the Multiplexer mode. LED for MUX mode MUX_ID:01 Press MUX button to enter Multiplexer mode MUX_ID:01 IN:01 PTZ Cam:001 1 1 11 01 trix trix atrix 1 1 D U SYS MUX / WIDE PgUp DVR FAR/ PIC.L / OPEN BACK N/ ON/ OPA AUT S ZOOM FOCU IRIS OFF/ / GRP / Rx ER POW T/ SHO SET/ MEN MUX NEX / ALM / RUN / AUX T/ E/ CLOS DEL PREV D/ HOL / NEAR PIC.
Basic OperationInitial Screen and Self-Testing After powered on, the dome starts the self-testing by slowly rotating and panning. After the selftest completes the initial information will be displayed on the screen. S/N:XXXXXXXXXXXXXXX CLINTON V2.
INITIAL INFO -----------------S/N: XXXXXXXXXXXXXXX CLINTON V2.42 PROTOCOL: CLINTON DOME ADDRESS: 001 COMM 9600, N, 8, 1 BACK EXIT DISPLAY SETUP --------------DOME LABEL PRESET LABEL ZOOM LABEL ZONE LABEL DIRECTION LABEL TEMPERATURE LABEL TIME LABEL DATE LABEL BACK EXIT DOME LABEL PRESET LABEL INITIAL INFO Shows the serial number, current firmware version and other settings.
CLEAR -----------------CLEAR ALL ZONES CLEAR ALL PRESETS CLEAR ALL PATTERNS CLEAR ALL TOURS CLEAR ALL WINDOWS FACTORY DEFAULTS RESTART BACK EXIT CLEAR The CLEAR function resets the stored settings and controls back to factory default. *NOTE: Pressing Right with the joystick will activate the following functions. There are no sub menus to these functions. You cannot undo the action.
CLOCK SETTING -----------------TIME 13:44:30 DATE 10/03/31 BACK EXIT CLOCK SETTING The system is equipped with a RTC (Real-Time Clock) and can be used to display the date/time information on the screen, or operated via schedule (see pg.18; “Time Running”). In order to use this function correctly, you must first set up the date and time. [TIME]: Change the time setting. Displayed as 24hr clock. [DATE]: Change the date setting. Displayed as Year/Month/Day.
Function Settings MAIN MENU -----------------SYSTEM SETTING --> CAMERA SETTING --> FUNCTION SETTING --> WINDOW BLANKING --> EXIT FUNCTION SETTING -----------------PRESETS --> SCAN --> PATTERNS --> TOUR --> ZONES --> TIME RUNNING --> BACK EXIT PRESETS -----------------PRESET NUMBER 001 SET PRESET --> SHOW PRESET CLEAR PRESET EDIT PRESET LABEL --> BACK EXIT In the function settings, user can setup the automated PTZ functions, such as preset position, tours, scan, etc.
SCAN -----------------SCAN NUMBER 01 SCAN SPEED 50 SET LEFT LIMIT --> SET RIGHT LIMIT --> CLEAR SCAN RUN SCAN EDIT SCAN LABEL --> BACK EXIT SCAN A Scan-Tour is an automated Pan movement between 2 defined positions with speed setting. The scan will move from the defined Left limit, to the defined Right limit in a straight path, and back again. If you wish to have your PTZ follow a more advanced path, use one of the next two selections: “PATTERN”, or “TOUR”.
TOUR -----------------TOUR NUMBER 001 EDIT TOUR --> RUN TOUR CLEAR TOUR BACK EXIT TOUR A Tour is an automated cruising through selected preset positions with individual speed settings and dwell times. This PTZ supports up to 4 tours with 24 positions each. *NOTE: Before a tour can be properly set up, you must first define your preset points you wish to include in the tour (see page 16 “Presets”).
TIME RUNNING -----------------TIME CHANNEL 1 START TIME 00:00 END TIME 00:00 RUNNING NONE BACK EXIT TIME RUNNING The time running function is a scheduled start for predefined action, such as preset tour, scan tour, etc. This PTZ supports up to 4 schedules.
OSD Map OSD MENU INDEX SYSTEM SETTING -----------------EDIT DOME LABEL --> INITIAL INFO --> DISPLAY SETUP --> MOTION --> CLEAR --> PASSWORD SETUP --> CLOCK SETTING --> COMM SETTING --> BACK EXIT EDIT DOME LABEL -----------------LABEL: DOME 1 BACK EXIT INITIAL INFO -----------------S/N: XXXXXXXXXXXXXXX CLINTON V2.
Specifications Model CE-PTZ10X Signal Format PAL / NTSC Scanning Progressive Image Sensor 1/4 inch Ex-View CCD H. Resolution 540 TVL Viewing Angle 46.0 º (Wide end) 4.6 º (Tele end) Zoom 10 x Optical / 12 x Digital Min. Illumination 1.0Lx (typical) - (F1.8, 50 IRE) Focus Auto / Manual White Balance Auto / Manual (ATW, Indoor, Outdoor, One Push WB, Manual WB) Shutter Speed 1 to 1/10,000 Sec.
v.09.23.