Instruction manual

Linddana A/S, Ølholm Bygade 70, DK-7160 Tørring, Telephone +45 75 80 52 00 Fax +45 75 80 54 11
Instructions: TP 150-200-250 dated 05.12.2005
Copyright 2001
35
PARAMETERS IN SEMI AUTOMATIC MODE
Name Meaning Remarks
L (ow) Minimum If the cutting wheel turns slower than the minimum speed, speed the
feeder will be stopped in order to give the cutting wheel the chance to regain
its normal speed . A value of f.e. P 10 means that the feeder will be stopped
when the speed falls to a value which is 10% lower than the normal speed.
Please note that there is no control if set to zero.
Valid values: 0-99%
n (ormal) Normal This parameter has to be set to zero in this operating mode. speed Valid
value: 0
H (igh) Maximum If the cutting wheel turns faster than the maximum speed, speed the
feeder will be stopped for safety reasons. A value of f.e. P 15 means that at a
speed which is 15% higher than the normal speed the feeder will be stopped.
Entering a zero means the maximum speed will not be controlled.
Valid values: 0...99%
Ret (urn) Return The return speed is the speed which restarts the feeder.
speed If you enter a value of P 05 this means the feeder starts
as soon as it reaches a speed that is 5% lower than the
normal speed.
Valid values: 1...99%
IPU Pulses per Number of pulses per revolution of the cutting wheel. The
revolution correct setting of this parameter is very important to get the
best performance. Values between 4 and 8 are
recommended. In case it´s not possible to realise these numbers of pulses for
mechanical reasons or if the performance of the HC 960 is not satisfactory,
please call for assistance. Make sure the frequency of your maximum speed
is not higher than the max. frequency of the sensor you are using.
Valid values: 1...255