7
KNIFE REPLACEMENT
Bolts per knife / total
M12x30-10.9
DIN 933
Unbrako
type MK
M12x45-12.9
DIN 7991
Unbrako type MK
M12x50-12.9
DIN 7991
Unbrako type MK
M12x55-12.9
DIN 7991
Flange nuts
M12
DIN 6331-10
Tightening torque
Max. [Nm / KPm]
TP 150 3/6 X 0 110 Nm / 11 KPm
TP 200 w/out sliver breaker 4/12
X 12 95 Nm / 9.5 KPm
TP 200 w/sliver breaker 4/12
X 12 95 Nm / 9.5 KPm
TP 250 w/out sliver breaker 5/15
X 15 95 Nm / 9.5 KPm
TP 250 w/sliver breaker 5/15
X 15 95 Nm / 9.5 KPm
Important!
Carefully clean the rotor disc and the bolting surfaces of knives before mounting.
When fitting, bolts must be lightly oiled (µ=0.125), i.e. with thin oil, spray oil or similar.
Copper grease, MoS
2
, or corresponding low-friction grease must not be used.
Use only ORIGINAL BOLTS
Only Unbrako countersunk bolts may be used!
Bolt life = Knife life
For safety reasons it is important that bolts be changed regularly at intervals corresponding to the life of a
set of knives. Therefore when new knives are purchased, new bolts and nuts are also supplied.
To ensure good chip quality it is important that knives and anvils remain sharp and intact. Daily
inspection is strongly recommended.