User guide
CX-A4 INSTALLATION AND OPERATION MANUAL  9 
15 General Specifications 
Inputs  Balanced via 3 pin XLR type connector. 
Outputs  2 pin plug-in screw terminal type connectors for flexible cables up to 
2.5mm² 
Protection  VI limiting, DC offset, Thermal and Switch-on Delay 
Status  LED indicators on each channel for Signal, Peak & Protect. 
Cooling  Force cooled using two speed DC fan. 
Dimensions  482.6mm x 88.0mm (2U) x 325.0mm deep (+ connectors) 
Weight 9kg net 
16 Technical Specifications 
Rated Output  120-watts/4 ohm load 85-watts/8 ohm load. 
Bridged Output  240 watts/8 ohm load 
Frequency Response  ±1dB 10Hz to 50kHz 
THD  <0.005% 1kHz <0.05% 20Hz/20kHz 8Ω 1dB below rated output
VCA Module THD  <0.03% 20Hz/20kHz 
Input Sensitivity  0dBu (775mV) 
Input Impedance  10kΩ balanced / 5kΩ unbalanced 
Noise    >90dB below rated output. 
Slew Rate  35V/μS (power amplifier) 
Power Input    230V ±5% (115V ±5% available) 
Fuse rating    230V - T4A H    115V - T8A H 
This product conforms to the following European EMC Standards: 
BS EN 55103-1:1997 
BS EN 55103-2:1997 
This product has been tested for use in commercial and light industrial environments. If the equipment 
is used in controlled EMC environments, the urban outdoors, heavy industrial environments or close to 
railways, transmitters, overhead power lines etc. the performance of the unit may be degraded. 
The product conforms to the following European electrical safety standard. 
BS EN 60065:1998 
Safety Considerations and Information 
The unit must be earthed. Ensure that the mains power supply provides an effective earth 
connection using a three wire termination. 
When the mains switch is in the off ‘O’ position the live and neutral conductors of the mains 
transformer are disconnected, however some parts of the product will still remain connected to 
the live and neutral mains conductors 
15-01-09 V10.0 