Installation Guide

DLM-1 Series Installation Guide V1.0
5
REAR CONTROLS AND CONNECTIONS
SETTINGS
1: MIC INPUT FILTER
2: FACTORY (NVM)
3: FACTORY (BOOT)
ON OFF
OFF
OFF
ON
ON
DEFAULT
7
8
7. Ethernet port – standard RJ45 network connector. Connect the DLM-1 to a Dante-compliant network here. The
connector has two LEDs:
Yellow – ON: data rate of 100 Mb/s in use (auto-negotiated with switch)
OFF: data rate of 10 Mb/s in use (auto-negotiated with switch)
Green – illuminates to indicate network activity. Sporadic illumination is normal.
8. SETTINGS – a 3-pole DIP switch: functions are as below. Default settings are in BOLD
SW FUNCTION ACTION
1 MIC INPUT FILTER
ON – 120 Hz hi-pass lter active (mic input only)
OFF – FILTER DISABLED
2 FACTORY (NVM)
Both switches should be OFF.
For factory use only: DO NOT CHANGE THESE SETTINGS.
3 FACTORY (BOOT)