11.4 LM-1 Mic/line plus remote control of music
signals.
The Cloud LM-1 is a remotely located active module with a balanced microphone input, a line
level music input and music source select & level controls (rather like a built in RSL-6). A
microphone priority switch provides the option to reduce the level of the music signal when the
mic is used. Use 9 core screened cable to wire the LM-1 to the 46/50. When an LM-1 is used
the music control switch should be set to the 'remote' position.
12 Microphone Priority over Facility Input
Mic 1 and Mic 2 have priority over facility input signals; should you wish to remove this priority set internal
jumper J14 (see diagram below) to the 'OFF' position.
When setting the jumper(s) please ensure that you:
Remove the mains cable from the rear of the product before removing the top panel.
Only reassemble the unit using screws identical to the original parts.
13
V6 070113
1
2
345
6789
FACILITYPORT
CABLE
SCREEN
123456789
10
LM-1
CONNECTOR PIN NUMBER
9 PIN SUB D 1 2 3 4 5 6 7 8 9 SHELL
LM-1 Terminals 1 2 7 6 4 9 10 8 5 3
LM-1 CONNECTION TABLE
J14: Microphone over Facility
audio priority
Location of Jumper J14