5.  Continue to hold the CLEAR button and complete the selection/deselection 
  process with the ZONE buttons.
6.  Release the CLEAR button once the selection is complete. The selected 
  zones will then be written to memory as the Disabled Group.
7.  LEDs for the selected zones will remain illuminated to conrm the selection. 
  Press CLEAR again to clear the display.
8.  Reset jumper J7 to OFF to prevent a second NVM reset on a subsequent 
  power-up. (It is better to leave the power on for this step.) Once a zone has 
  been disabled, it will be inaccessible to that PM, either via the ZONE and 
  GROUP buttons, or via CALL ALL.
NOTE: Any subsequent NVM reset will clear the Disable Group, thus zones will 
need to be re-disabled.
Terminating the Digital Paging Interface
The Cloud Digital Paging Interface must be correctly terminated at its ends for error 
free operation. In systems using a single PM connected to a host mixer via the digital 
interface (such as the Cloud DCM-1), the terminations should be ON in both the PM 
and the mixer. In systems with multiple PMs, only the mixer and the PM at the “end” 
of the chain should have their terminations set ON; “intermediate” PMs should have 
their terminations set to OFF.
CDPM
GAIN (dB)
IN
THRU
-10
+10
INOUT
OUT
Mixer
Mixer
OUT
OUT
Termination ON
Termination ON
Termination OFF
CDPM
IN
THRU
CDPM
IN
THRU
DCM-1 #2
DCM-1 #1
Termination ON
Termination
ON
Termination ON
Termination OFF
Termination
ON
CDPM
GAIN (dB)
IN
THRU
-10
+10