Tone Generator
Test Signal Level
40 dB below max amp
output
Injected post level controls,
other channels muted.
Frequency range 60 Hz to 20 kHz in 1/3-octave steps
Sensitivity 1 to 100 Ohm detection
Signal detector
Sensitivity -30 dBu to +10 dBu 20 Hz to 20 kHz
Networking
DHCP Not supported
Data rates 10 BaseT or 100 Base T (automatic selection)
Connector RJ45; Auto MDI/MDIX
eMail protocols SMTP (no encryption)
Supported Ampliers
VTX4120, VTX4240, VTX4400
Recordable Events
Over temperature (90°C), Power on/off, Email error, Load Test pass/fail