User guide
8  
Z4
II
 & Z8
II
:
 Installation and User Guide 
22/10/04 V9
If the mixer has a CPM paging microphone installed, you have the option to power the 
microphone with the ‘CPM-PSU’ external power supply. This will reduce the load on the 
system by 40mA. If a power supply failure occurs switch off the mixer and disconnect the 
remote modules, the mixer should be left off for approximately 30 seconds to allow it to 
reset. Check the wiring and total current consumption of the external active devices before 
reconnecting the power and if the problem persists contact our technical department. 
20 Microphone Priority over Facility Input
Every vertically oriented zone board has a jumper marked J4 - this jumper sets the 
microphone over facility signal priority. In the OFF position (default) all microphones will not 
override the signals of the facility input (i.e. AE-1, DM-1 or LM-1). In the ON position, MIC 1, 
MIC 2 and the paging mic have a 30dB priority over the facility input. 
When setting the jumper(s) please ensure that you: 
• 
Remove the mains cable from the rear of the product before removing the top panel.
• 
Only reassemble the unit using screws identical to the original parts.
21 Remote Music Mute – Fire Alarm Interface 
In certain circumstances, there may be a requirement to mute the music signals via a fire 
alarm control panel in an alarm condition. The Cloud Venue Mixer provides a facility to mute 
the music signals by connecting the two pole music mute connector to a pair of relay 
contacts that are controlled by the fire alarm control panel. The jumper J4 on the mother 
board (adjacent to the power transformer) selects N/O (normally open – default) or N/C 
(normally closed) contact arrangements. The two-wire connection should not be connected 
to any other circuit or voltage. In most instances, the fire alarm company will provide the 
relay. All the microphone facilities operate normally when the music mute is operating. 
22 Installing RSL-6 or RL-1 Remote controls 
The remote control plates, RSL-6 and RL-1 are compatible with UK domestic electrical 
accessories and can be mounted onto a standard British flush or surface mounted 25mm 
deep back box. Two-core cable with overall screen should be used to connect the remote 
controls to the Cloud Mixer; because 
both functions are voltage controlled, 
a cable length of up to 100 metres can 
be used. When using the RSL-6 
remote control plate, the ‘music 
control’ switch (on the mixer rear 
panel) should be in the ‘remote’ 
position. If you propose to use the RL-
1 remote level control on any zone, 
set the ‘music control’ switch to the 
‘remote’ position and the PCB 
mounted jumper J1 on the respective 
zone board to the ‘FR’ position to 
allow front panel control of the music 
source. 
When setting the jumper(s) please 
ensure that you: 
• 
Remove the mains cable from the 
rear of the product before 
removing the top panel.
• 
Only reassemble the unit using 
screws identical to the original 
parts.
MUSIC CONTROL SWITCH SHOULD
BE SET TO THE 'REMOTE' POSITION
STANDARD WIRING CONVENTION
USE TWO CORE SCREENED CABLE
REMOTE CONTROL OF MUSIC SOURCE AND LEVEL
MUSIC CONTROL
REMOTE
(IN)
MIXER
3 POLE
CONNECTOR
RSL-6
1
2
3
1
2
3
FOR APPLICATIONS THAT REQUIRE
REMOTE CONTROL OF THE MUSIC
LEVEL WITH FRONT PANEL SOURCE 
SELECTION
REMOVE POWER CABLE BEFORE MAKING ANY INTERNAL ADJUSTMENTS
PCB JUMPER J1 SHOULD BE SET
TO THE 'FR' POSITION
SOURCE
SELECT
J1
ATTENTION!
MUSIC CONTROL SWITCH SHOULD
BE SET IN THE 'REMOTE' POSITION
MUSIC CONTROL
REMOTE
(IN)
RL-1
REMOTE CONTROL OF MUSIC LEVEL 
(WITH FRONT PANEL SOURCE SELECTION)
MIXER
3 POLE
CONNECTOR
FR SW
1
2
3
1
2
3