User guide

16
Z4
II
& Z8
II
:
Installation and User Guide
22/10/04 V9
27 EMC Considerations
The Cloud Z4 & Z8 fully conform to the relevant electromagnetic compatibility (EMC)
standards and are technically well behaved; you should experience no operational problems
and under normal circumstances, no special precautions need to be taken. If the unit is to be
used within close proximity to potential sources of HF disturbance such as high power
communications transmitters, radar stations and the like, the performance of the mixer may
be reduced; we suggest that the microphone cable screen be connected to the shell of the
XLR type connector and the line input leads are kept as short as possible.
28 Technical Specifications
Line inputs
Frequency Response
20Hz-20kHz
±
0.5dB
Distortion
<0.05% 20Hz -20kHz
Sensitivity
195mV (-12dBu) to 2.0V (+8dBu)
Input Gain Control
20dB range
Input Impedance
47k
Headroom
>20dB
Noise
-90dB A weighted (0dB gain)
Equalisation
HF:
±
10dB/10kHz LF:
±
10dB/50Hz
Microphone Inputs
Frequency Response
100Hz / -3dB(filter) 20kHz
±
0.5dB
Distortion
<0.05% 20Hz-20kHz
Gain Range
10dB-50dB
Input Impedance
>2k
(balanced)
Phantom power
+15V (PCB jumper for on/off)
Headroom
>20dB
Noise
-120dB EIN 22Hz-22kHz (150
)
Equalisation
HF:
±
10dB/5kHz LF:
±
10dB/100Hz
Facility Input
Input Impedance
10k
(balanced) pin 3(+) pin 4(-)
Sensitivity
0dBu 775mV
Noise Gate
Ground pin 5 to open
Outputs
Balanced Zone Outputs
775mV (0dBu) 3 pin Phoenixtype connector
Minimum load impedance
600 ohms
Maximum output level
+20dBu (7.75V)
29 General Specifications
Power input
230V
±
10% 115V
±
10% AC 40-60Hz
Fuse rating
Z8: 230V T125mA H 115V T250mA H
Z4: 230V T100mA H 115V T200mA H
Fuse type
20mm x 5mm 250V
Dimensions
482.60mm x 132.50mm(3U) x 160.00mm deep
(+ connectors)
Weight
Z4 3.83 kg net
Z8 4.40 kg net