MODEL CMA-180UC INSTALLATION & OPERATION Rev 1.13 CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-895-2141 www.cmadishmachines.
TABLE OF CONTENTS MODEL CMA-180UC 1. 2. 3. SPECIFICATIONS ........................................................................................ 2 1.1. CMA-180UC ......................................................................................................................... 2 1.2. CMA-180UC OPERATIONAL CYCLE ...................................................................................... 3 GETTING STARTED................................................................................
1. Specifications 1.1. METRIC EQUIVALENT CMA-180UC WATER CONSUMPTION PER RACK .86 GAL. (3.25 L) PER HOUR 20.6 GAL. (77.8 L) WASH TIME-SEC 94 94 RINSE TIME-SEC 16 16 DWELL TIME-SEC 10 10 2 MIN. 2 MIN. 30 30 WASH TANK CAPACITY 2.5 GAL. (9.46 L) PUMP CAPACITY 38 GPM (144 LPM) 140°F (60°C) OPERATING CYCLE TOTAL CYCLE OPERATING CAPACITY RACKS PER HOUR WATER REQUIREMENTS WATER INLET ½” — DRAIN CONNECTION 1” — 24 PSI 1.
1.2. CMA-180UC Operational Cycle The CMA-180UC Operational Cycle has a total cycle time of 2 minutes (120 seconds). The Timing Diagram and the steps listed below detail the individual functions that are executed during each Operational Cycle. Seconds: 0 10 20 30 40 50 60 70 80 90 100 110 120 Instant Start Relay Cam Timer Motor Cam Rinse Cycle Cam Wash Cycle Cam Optional Drain Pump Cam 1. With the machine powered up toggling the START switch begins a cycle.
Getting Started 2. Getting Started 2.1. Introduction to CMA-180UC The CMA-180UC is a hot water sanitizing, single rack, under-counter dishmachine. It is a standalone machine featuring a self-contained booster heater. The only external connections necessary are power supply, water supply, drainpipe, and optional chemical dispensers. The machine uses re-circulated wash water and fresh water final-rinse. Operation of the CMA-180UC is extremely user friendly.
Getting Started 2.2. Receiving and Installation The dishwasher is shipped from the factory in a corrugated box on a wooden pallet. The installation guidelines give a systematic procedure for setting up the machine. Start by removing the packaging material. Unwrap the machine and check for the following component parts: The Wash Tank Scrap Screen is shipped inside the wash cavity of the machine. This screen must be in place during operation. It has been designed to perform two basic functions: 1.
Getting Started i. Run an appropriate length of ½” conduit from your dispenser to the mounting plate where it will be secured. The conduit needs to be of sufficient length and flexibility to permit the machine to be moved for cleaning without having to disconnect any wiring. ii. Run your dispenser wires from the conduit through the enclosed area across the top of the machine and feed them through the access hole provided in the back of the control panel drawer. 2.
Getting Started 2.2.4. NOVA Detergent and Rinse Dispenser (Optional) 1 . The NOVA Detergent and Rinse Dispenser has its own reference manual. Familiarize yourself with the dispenser’s reference manual before proceeding with installation. 1. The NOVA dispenser is pre-wired with a multi-conductor electrical cable that is to be run through a conduit to the power block inside the control panel drawer. Use a ½” watertight conduit meeting all local and national codes.
Getting Started Brown (LIVE) wire Multi-conductor cable Rinse Signal wires (Blue terminals) Detergent Signal wires (Red terminals) Black (Main Power) Gray/Violet (Main Power Neutral) (Same terminal as rinse neutral) Note: Machine Neutral (White wires) Figure 2.2.4 Note: In Figure 2.2.4 the machine’s wire harness was left out of the back of the power block to more clearly show the dispenser wires. 2.
Getting Started 2.2.5. Water Tempering Kit MODEL CMA-180UC INSTALLATION & OPERATION MANUAL Rev. 1.
Getting Started 2.2.6. Booster Heater Setup The booster tank must be filled with water before the heating element is energized. For this reason the “High Limit Switch” has intentionally been activated at the factory and will require resetting before the heating element will turn on. Follow the procedure below to complete the initial installation: 1. Close the door on the machine. 2. Turn the Power switch to the "ON" position. 3. Hold the “FILL” switch in until water overflows into the scrap tray. 4.
Operation 3. Operation 3.1. Initial Setup 3.1.1. Rinse Pressure Regulator The CMA-180UC requires a supply water input pressure of 24 PSI minimum. This pressure is then reduced by the supply water regulator. Use the following procedure to adjust the rinse pressure to 20 PSI: 1. Close the door on the machine. 2. Turn the Power switch to the "ON" position. 3. While holding the “FILL” switch—to activate the water solenoid—adjust the pressure regulator until the gauge reads 20 PSI.
Operation 3.3. Operating and Cleaning Instructions MODEL CMA-180UC INSTALLATION & OPERATION MANUAL Rev. 1.
Operation 3.4. Preventive Maintenance Chart MODEL CMA-180UC INSTALLATION & OPERATION MANUAL Rev. 1.
Operation 3.5. Quick service guide MODEL: CMA 180UC HIGH TEMP UNDER COUNTER TECHNICAL ISSUE CAUSE SOLUTION Pressure regulator is not set properly Set regulator to 18-20 psi Faulty rinse micro switch Replace micro switch, P/N 00411.00 Drain hose elevated too high Must be lowered to goose neck level Obstruction in drain hose Check hose & clean Scrap exit screen Clean exit screen Faulty drain pump Replace pump, P/N 15503.
Operation 3.6. Troubleshooting PROBLEM LIKELY CAUSE SOLUTION Machine inoperative Power off at circuit breaker Reset circuit breaker Defective power switch Replace power switch P/N: 15521.50 Motor inoperative Door is open Close door Control panel is pulled out Secure control panel Defective reed switch Replace reed switch P/N: 00557.55 Defective timer assembly Replace timer assembly* P/N: 14408.80 Defective pump motor contactor Replace contactor P/N: 15504.
Operation PROBLEM LIKELY CAUSE SOLUTION Low heat during operation Low incoming water temperature Turn up supply water heater (below 140° F) Insulate supply water pipe Thermostat out of adjustment Adjust thermostat Cold water mixing with supply Isolate hot water from cold water Defective heater Replace heater P/N: 15517.
Operation PROBLEM LIKELY CAUSE SOLUTION Start switch requires > 1 second activation to run cycle Defective (Instant Start) ice cube relay P/N: 00631.00 Activating fill switch does not fill machine Defective drain/fill switch Replace drain/fill switch Replace ice cube relay P/N: 15522.00 Defective water solenoid valve Replace water solenoid valve P/N: 03603.10 Fill (rinse water) won’t shut off Defective water solenoid valve Replace water solenoid valve P/N: 03603.
4. Parts Kit 4.1. Initial Parts Kit (P/N 1100.66) P/N DESCRIPTION Qty 15504.00 Motor Contactor, 2-Pole 20 Amp 1 15504.50 Heater Contactor, 2-Pole 35 Amp 1 00501.00 2-Minute Timer Motor 1 00631.00 Ice Cube Relay 120 V 1 15521.00 Rocker Switch Start Momentary 1 15522.00 Rocker Switch Drain/Fill 1 15521.50 Rocker Switch Power Maintained 1 00557.55 Reed Switch 1 03623.00 1/2” Vacuum Breaker Repair Kit – Watts 1 00707.00 1/2” Water Solenoid Repair Kit – J/E 1 04103.
Parts Manual 4.2. ITEM NO. NO. REQ’D 1 1 Optional Drain Pump Kit P/N 15503.00 DESCRIPTION Drain Motor Ultra Jet for CMA-180UC ITEM NO. NO. REQ’D 6 4 P/N 03101.00 DESCRIPTION Hose Clamp 1” 2 2 00432.50 Twist Tie 7 1 15603.00 Drain Line Gooseneck 3 1 15601.10 Black Drain Hose 1" ID X 3 1/2" 8 2 03801.10 10-32 SS Nut 9 2 04806.00 #10 Brass Washer 4 1 15601.50 Drain Hose 1" ID, 6 ft 5 1 15601.60 Robber Hose 90 Deg. MODEL CMA-180UC INSTALLATION & OPERATION MANUAL Rev. 1.
Parts Manual 4.3. Optional Drain Pump—INSTALLATION INSTRUCTIONS 1. Start by removing the existing drain hose from the Drain Valve as shown in Figure 1. From Scrap Tray Remove From Wash Tank Figure 1 2. Locate the white and purple wires that are safe-ended and tie-wrapped at the top of the Drain Pump compartment. Bring these wires out so they can be connected after mounting the Drain Pump. 3.
Parts Manual 5. Secure the drain gooseneck to the wash riser pipe with the hose clamp provided as shown in Figure 3. Secure with hose clamp Figure 3 6. Route the drain hose to the drain and provide a 1-inch air gap at the drain. MODEL CMA-180UC INSTALLATION & OPERATION MANUAL Rev. 1.
5. Customer Notice CMA-180UC Installation Guidelines Improper installation of this product may void the warranty on this machine. Please follow these guidelines for recommended installation and to ensure the warranty of this model is authorized by CMA Dishmachines. Dishmachine Installation Requirements 1. Machine must be level. Adjust leveling feet to accommodate uneven floor surfaces. 2. Drain height should not exceed maximum height of 16”.
Electrical Diagram 6. Electrical Diagram MODEL CMA-180UC INSTALLATION & OPERATION MANUAL Rev. 1.
Electrical Diagram MODEL CMA-180UC INSTALLATION & OPERATION MANUAL Rev. 1.